1.
Intended Use .......................................................3
2.
Installation Requirements...................................3
3.
AC-Input...............................................................4
4.
Input Inrush Current ...........................................5
5.
Output .................................................................6
6.
Hold-up Time.......................................................7
7.
DC-Input...............................................................7
8.
Efficiency and Power Losses................................8
9.
Functional Diagram.............................................9
10. Front Side and User Elements.............................9
11. Terminals and Wiring........................................10
12. Lifetime Expectancy and MTBF.........................10
13. EMC ....................................................................11
14. Environment ......................................................12
15. Protection Features ...........................................13
16. Safety Features ..................................................13
17. Dielectric Strength ............................................14
18. Certifications ....................................................15
Terminology and Abbreviations
• PE and
symbol-PE is the abbreviation for Protective Earth and has the same meaning as the symbol
• Earth, Ground-This document uses the term "earth" which is the same as the U.S. term "ground".
• T.b.d.-To be defined, value or description will follow later.
• AC 230V-A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%)
included. E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V)
• 230Vac-A figure with the unit (Vac) at the end is a momentary figure without any additional tolerances included.
• 50Hz vs. 60Hz-As long as not otherwise stated, AC 230V parameters are valid at 50Hz mains frequency.
• may-A key word indicating flexibility of choice with no implied preference.
• shall-A key word indicating a mandatory requirement.
• should-A key word indicating flexibility of choice with a strongly preferred implementation.
P
a
g
e
19. Physical Dimensions and Weight ..................... 16
20. Application Notes ............................................. 17
20.1. Peak Current Capability ...........................17
20.2. Back-feeding Loads ..................................17
20.4. External Input Protection .........................18
20.6. Daisy Chaining of Outputs .......................19
20.8. Series Operation .......................................20
20.9. Operation on Two Phases ........................20
20.12. Mounting Orientations ............................22
P
a
g
e
...............................18
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Allen-Bradley 1606-XLP60BQ and is the answer not in the manual?

Questions and answers

Summary of Contents for Rockwell Automation Allen-Bradley 1606-XLP60BQ

  • Page 1: Table Of Contents

    Reference Manual Bulletin 1606 Switched Mode Power Supplies Catalog Number: 1606-XLP60BQ Index Intended Use ............3 19. Physical Dimensions and Weight ..... 16 Installation Requirements........3 20. Application Notes ..........17 AC-Input...............4 20.1. Peak Current Capability ......17 Input Inrush Current ...........5 20.2. Back-feeding Loads ........17 Output ..............6 20.3.
  • Page 2 45x75x91mm WxHxD Weight 250g / 0.55lb Catalog Numbers Certification Marks 1606-XLP60BQ 12-15V Standard unit Power Supply UL 60950-1 Marine RINA Marine Ind. Cont. Eq. UL 508 Class 2 EMC, LVD GOST R C-Tick Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 3: Intended Use

    All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 4: Ac-Input

    230Vac c) 230Vac 0.55 0.50 0.45 Output Current Output Current 0.40 4.5A 4.5A All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 5: Input Inrush Current

    Middle curve: Input voltage 100V/DIV Lower curve: Output voltage 2.5V/DIV Time basis: 20ms / DIV All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 6: Output

    22.5A for 2ms, resistive load typ. from 12V to 3.2V at 22.5A for 5ms, resistive load All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 7: Hold-Up Time

    Power Supply internal fused Load (a) Continuous (b) Short-term Input Voltage Vdc 130Vdc All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 8: Efficiency And Power Losses

    4.5A, typ. typ. Efficiency Power Losses Input Voltage Input Voltage 225 260Vac 225 260Vac All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 9: Functional Diagram

    D Output voltage potentiometer (single turn potentiometer) Turn to set the output voltage. Factory set: 12.0V All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 10: Terminals And Wiring

    100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 11: Emc

    100kHz, min. 45kHz, max. 160kHz Input voltage and output load dependent All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 12: Environment

    B... Tamb < 50°C C... Tamb < 40°C Ambient Temperature Altitude 70°C 2000 4000 6000m All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 13: Protection Features

    < 0.41mA / 0.85mA 264Vac, 50Hz, TN-,TT-mains / IT-mains Double or reinforced insulation All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 14: Dielectric Strength

    This helps to avoid situations in which a load starts unexpectedly or can not be switched off when unnoticed earth faults occur. All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 15: Certifications

    Product certification information (including Certificates and Declarations of Conformity) can be found at www.ab.com/certifications. All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 16: Physical Dimensions And Weight

    Installation Clearances See section 2. Fig. 19-1 Front view Fig. 19-2 Side view All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 17: Application Notes

    The maximum allowed feed-back-voltage is 25Vdc. The absorbing energy can be calculated according to the built-in large sized output capacitor which is specified in section 5. All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 18: Charging Batteries

    EMI, inrush current and harmonics will increase when using multiple power supplies in parallel. All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 19: Daisy Chaining Of Outputs

    The unit is designed to supply any type of load, including unlimited capacitive and inductive loads. All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 20: Series Operation

    Fig. 20-5 Grounded input Fig. 20-6 Ungrounded input Spike Surge Surge Power Supply Power Supply Ground All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 21: Use In A Tightly Sealed Enclosure

    41.1°C (in the middle of the right side of the power supply with a distance of 1cm) Temperature outside the box: 21.9°C Temperature rise: 19.2K All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 22: Mounting Orientations

    60°C Fig. 20-11 Output Power Mounting Orientation E (Horizontal ccw) Ambient Temperature 60°C All parameters are specified at 12V, 4.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise. Rockwell Automation Publication 1606-RM015A-EN-P — March 2014...
  • Page 24 Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to help ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.