Net Sonde - Furuno FCV-1900G Installation Manual

Fish finder/hi-res fish finder, fish size indicator
Hide thumbs Also See for FCV-1900G:
Table of Contents

Advertisement

2.4

Net Sonde

Connect the net sonde FNZ-18 or FNZ-28 to the WAGO connector CN-6 in the con-
nector box inside the processor unit. Connect the net sonde to the display unit with a
TTYCSLA-4 cable (Japanese Industrial Standards cable or equivalent cable). The fol-
lowing procedure shows how to connect the cables from the net sonde to the proces-
sor unit.
1. Fabricate the TTYCSLA-4 cable ends referring to the figure below.
2. Unfasten three binding screws to remove the cover of the processor unit.
3. Detach the WAGO connector for the net sonde (CN-6),
4. Connect the cable cores to the WAGO connector referring to the interconnection
diagram.
5. Reattach the WAGO connector.
6. Unfasten the screws on the cable clamp, then fix the cables with the cable clamp.
7. Close the cover of the processor unit.
8. Fit a connector to the loose end of the net sonde display's cable, then connect the
cable to the net sonde display unit.
Note: When connecting an analog net sonde
signal to the FCV-1900, the net sonde display
unit must be modified. Attach an 820 ohm resis-
tor (±5%, 1/4W or more) in parallel with R36 (1k
ohm) on the MAIN board 11P1118. Fix the resis-
tor on rear side of the board as follows.
Front
150
Armor
Vinyl sheath
10
15
Vinyl tape
R36
250
Twisted core
Drain wire
Plastic tube
KP-H
KP-C
Rear
Solder the resistor with parallel on R36.
17
2. WIRING
6
6
820
(±0.5%,1/4W)
R36 1k
U31
1
2