MANUAL COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours. If you should ever need to contact us concerning this unit, it will help us to respond to your needs faster.
Should you experience a problem please follow the PREPARING THE UNIT “Troubleshooting Tables” near the end of this manual. The warranty listed in the manual describes what you can UNPACKING expect from WINCO should you need service assistance in LUBRICATION the future. OIL RECOMMENDATIONS OIL ALERT SYSTEM...
TESTING POLICY GENERATOR Before any generator is shipped from the factory, it is fully checked for performance. The generator is loaded to its Model W10000VE/B full capacity, and the voltage, current, and frequency are W10000VE-03/A carefully checked. Surge Watts 10,000...
SAFETY INFORMATION E. Store fuel only in an approved container, and only in a well ventilated area. This engine generator set has been designed and F. Follow local codes for closeness to combustible manufactured to allow safe, reliable performance. Poor material.
UNIT CAPABILITIES INTENDED USES GENERATOR CONNECTIONS W10000VE/B: 120 Volt and 240 Volt receptacles are This engine generator set has been designed primarily for provided for connection to various loads. The diagram portable heavy duty commercial use. Both 120 volt and 240 below represents this 9,600 watt (rated output) generator.
WINCO take care of the freight claim. If you sign for the unit, the transfer of the ownership requires that you file the freight claim OIL ALERT SYSTEM 2.
AUTOMATIC VOLTAGE REGULATOR cable to the “bat-” terminal. Make sure all connections are clean an tight. Reverse the sequence when disconnecting, disconnect the negative cable first. These engines produce enough direct current to keep the battery charged under normal operating conditions, but were not intended to be used as a battery charger.
INITIAL START UP NOTE: The starter life is improved by using shorter cycles with time to cool off between cranking cycles. Do NOT operate the starter more than 15 seconds during each The throttle control on these generators is preset and minute.
DO NOT operate this unit inside a home or garage, near vents or windows, Your WINCO portable generator ships with a bonded or anywhere carbon monoxide gas could accumulate. neutral. You can safely use this generator without external grounding as long as all loads are powered through the receptacle panel.
The transfer switch prevents damage to the generator and the other circuit components if main line power is restored The WINCO YourGen meter allows you to see useful while the generator is connected. Installing a transfer information about your generator from the front panel switch also permits the use of normal fusing.
Page 11
The speed of the engine was carefully adjusted at the 120 Volt and 240 Volt receptacles are provided for factory so that the generator produces the proper voltage connection to various loads. and frequency. For normal usage, the speed setting should not be changed.
Start the engine and warm it up, stop the engine Outdoor temperatures determine the proper oil viscosity for the engines. Winco recommends our 5W-30 fully synthetic and remove the spark plug wire to prevent it oil to give you excellent protection in cold temperatures from accidently being started.
SPARK PLUG C. Remove the oil filter and dispose of it properly. D. Before you install the new oil filter, clean the filter mounting base and coat the seal of the new oil filter Replace annually or every 100 above hours of operation. will clean engine oil.
GENERATOR CARE TROUBLESHOOTING Problem Possible Causes Proper care and maintenance of the generator is necessary Won’t start Low oil level to ensure a long trouble free life. Fouled spark plug Out of fuel EXERCISING THE GENERATOR Start switch in OFF position Fuel Valve turned off The generator should be operated every three to four Plugged fuel filter...
WINCO written instructions and applicable codes. WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the product. At WINCO’s option, material found to be defective in material or workmanship under normal use and service will be repaired or replaced.