Advertisement

MANUAL
ENGLISH
Net-2 Panel, 3-pin
V1
Order code: 50812/50814
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands

Advertisement

Table of Contents
loading

Summary of Contents for SHOWTEC NET-2 3-pin

  • Page 1 MANUAL ENGLISH Net-2 Panel, 3-pin Order code: 50812/50814 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2: Table Of Contents

    Net-2 Panel, 3-pin Table of contents Warning ....................................2 Safety Instructions ................................. 2 Operating Determinations ............................3 Connection with the mains............................4 Return Procedure ................................4 Claims ....................................4 Description of the Device ..............................5 Overview ..................................5 Front ....................................6 Installation ...................................
  • Page 3: Warning

    Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. Your shipment includes: ● Showtec Net-2 Panel, 3-pin ● User manual Safety Instructions Every person involved with the installation, operation and maintenance of this device has to: ●...
  • Page 4: Operating Determinations

    ● If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service.
  • Page 5: Connection With The Mains

    Net-2 Panel, 3-pin Connection with the mains Connect the device to the mains with the Phoenix terminal block. Always pay attention, that the right color cable is connected to the right place. International EU Cable UK Cable US Cable BROWN YELLOW/COPPER PHASE BLUE...
  • Page 6: Description Of The Device

    Description of the Device Features The Showtec Net-2 Panel is a cutting-edge network routing device which converts Art-Net or sACN to DMX-512 and vice versa. It is suitable for fixed installations and for making multiple patch points for DMX inputs or outputs in professional theaters, schools, universities, convention halls, clubs or churches. It allows for the transmission of a maximum of 1024 DMX channels over a single Ethernet cable.
  • Page 7: Front

    Net-2 Panel, 3-pin Front Fig. 02 01) DMX LED indicator This indicator lights up when there is DMX signal present on DMX ports A and B. 02) Link LED indicator This indicator lights up when a network signal is received. 03) OLED display + control buttons 04) Power LED indicator This indicator lights up when the device is powered.
  • Page 8: Installation

    Net-2 Panel, 3-pin Installation Remove all packing materials from the Net-2 Panel. Check that all foam and plastic padding is removed. The Net-2 Panel can be powered from the Ethernet connection, using Power-over-Ethernet (PoE) technology. If the network switch does not support PoE, you can use a PoE injector or the 12–36 V DC connector.
  • Page 9: Setup And Operation

    Net-2 Panel, 3-pin Setup and Operation Follow the directions below, as they pertain to your preferred operation mode. Before plugging the unit in, always make sure that the power supply matches the product specification voltage. Setup Setup Net-2 Panel with Laptop/PC 01) Connect the Net-2 Panel to the DMX inputs on the fixtures, using an XLR cable.
  • Page 10: Setup Net-2 Panel With Lighting Controller

    Net-2 Panel, 3-pin Setup Net-2 Panel with Lighting Controller 01) Connect the Net-2 Panel to the DMX inputs on the fixtures, using an XLR cable. 02) Connect the Net-2 Panel to a network switch using a CAT5/CAT6 cable. 03) Connect the network switch to the lighting controller using a CAT5/CAT6 cable. If no network is required, you can connect the Net-2 Panel directly to the lighting controller, using a CAT5/CAT6 cable.
  • Page 11: Connecting To A Network

    Net-2 Panel, 3-pin Connecting to a Network Art-Net Settings 01) Connect the device’s Ethernet connector to a network switch, using a CAT5/CAT6 cable. 02) Set the IP address of your computer/lighting controller to 2.x.x.x or 10.x.x.x, depending on the Art- Net settings.
  • Page 12: Supported Pinout Modes

    Net-2 Panel, 3-pin Supported Pinout Modes The Net-2 Panel supports the following 2 pinout modes: 10/100 mode A and 10/100 mode B. Fig. 08 Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows of two or more fixtures set to a master/slave operating mode.
  • Page 13: Operation

    Net-2 Panel, 3-pin Operation The Net-2 Panel can be configured to convert DMX signals into Art-Net or sACN and vice versa. The following configuration options are possible: ● Convert Art-Net/sACN to 2 x DMX outputs ● Convert 2 x DMX inputs to Art-Net/sACN ●...
  • Page 14: Control Panel

    Net-2 Panel, 3-pin Control Panel A) OLED display ENTER button C) DOWN button D) UP button MENU button Fig. 09 ● Use the UP/DOWN buttons to navigate through the menus, to increase/decrease numeric values or to scroll through a set of characters. ●...
  • Page 15: Menu Overview

    Net-2 Panel, 3-pin Menu Overview Order code: 50812/50814...
  • Page 16: Main Menu Options

    Net-2 Panel, 3-pin Main Menu Options The Main Menu has the following options: Press the UP/DOWN buttons to navigate through the Main Menu. Press the ENTER button to open the submenu. Press the MENU button to return to the Main Menu. 1.
  • Page 17: Dhcp Ip

    Net-2 Panel, 3-pin 2.1. DHCP IP If you choose DHCP IP, the IP address of the device will be generated automatically by the network server. 2.2. Manual IP To configure the IP address of the device manually: 01) Press the UP/DOWN buttons to move the cursor respectively to the left or to the right on the display. When the cursor reaches the last available position on the line, it will move to the second line.
  • Page 18: Set Dmx Port

    Net-2 Panel, 3-pin 4. Set DMX Port In this menu you can configure the 2 DMX ports. 01) Press the UP/DOWN buttons to choose between Port 1 and Port 2. 02) Press the ENTER button to confirm your choice. The display shows: 03) Press the UP/DOWN buttons to scroll between the following settings: 1.
  • Page 19: Set Display

    Net-2 Panel, 3-pin 5. Set Display In this menu you can set the orientation of the OLED display and the amount of time the backlight stays on after the last button is pressed on the control panel. 01) Press the UP/DOWN buttons to toggle between the 2 options: 1.
  • Page 20: Settings Configuration Via Web Browser

    Net-2 Panel, 3-pin Settings Configuration via Web Browser The Net-2 Panel can be configured remotely via web interface. 01) Connect the Net-2 Panel to a laptop/computer. 02) Configure the network address of the laptop /computer in the correct range (IP 2.x.x.x or 10.x.x.x and Subnet 255.0.0.0).
  • Page 21: Changing The Password

    03) The electric power supply cables must not show any damages or material fatigue. The Showtec Net-2 Panel requires almost no maintenance. However, you should keep the unit clean. Disconnect the mains power supply and then wipe the cover with a damp cloth. Wipe the front glass panel clean with glass cleaner and a soft cloth.
  • Page 22: Troubleshooting

    This troubleshooting guide is meant to help solve simple problems. If you are unable to determine the cause of the problem, do not open the unit, as this may damage the device and the warranty will be deemed void. Return the device to your Showtec dealer. Problem...
  • Page 23: Product Specifications

    Net-2 Panel, 3-pin Product Specifications Model: Showtec Net-2 Panel Power supply: 12–36 V DC, 500 mA or PoE (802.3af) Power consumption: Dimensions: 113 x 113 x 33 mm (LxWxH) Weight: 0,13 kg Operation and programming DMX: 2 universes (IN and/or OUT)
  • Page 24: Dimensions

    Net-2 Panel, 3-pin Dimensions Order code: 50812/50814...
  • Page 25: Notes

    Net-2 Panel, 3-pin Notes Order code: 50812/50814...
  • Page 26 Net-2 Panel, 3-pin Order code: 50812/50814...
  • Page 27 Net-2 Panel, 3-pin Order code: 50812/50814...
  • Page 28 ©2020 Showtec...

This manual is also suitable for:

5081250814

Table of Contents