3) Use the "L" shaped brush to push the sediment through the drain valve to keep the drain clear. Hose off the heat
exchanger and vat walls until all sediment and debris has been flushed through the drain into the filter tub.
4) Turn the RIGHT HAND Topside Shortening Return Lever 1⁄4 turn counter clock wise; then CAREFULLY
remove the Wash Down Hose MALE In-Line Plug from the TOPSIDE FEMALE SOCKET by depressing
the Topside Socket Release Knob.
5) Hang the Wash Down Hose in an up-right position so shortening can drain into a metal container; then proceed
to paragraph B 1 page 42.
b.
Fryer WITH an Automatic Vat Cleaner (AVC).
1) With the Drain Valve in the OPEN position, CAREFULLY place the AVC (Spray Blaster) on the fryer's TOPSIDE
HANGER BRACKET and SECURELY connect the MALE In-Line Plug on the AVC to the TOPSIDE FEMALE
SOCKET.
2) Turn the RIGHT HAND Topside Shortening Return Lever 1⁄4 turn counter clock wise to allow shortening in the
filter tub to be discharged into the vat through the four (4) nozzles in the bottom of the spray blaster, flushing
sediment and debris through the drain valve. When all sediment and debris has been flushed from the vat, turn the
Topside Shortening Return Lever 1⁄4 turn clock wise, remove the male in-line plug on the Spray Blaster from the
Topside Female Socket by depressing the Topside Release Knob.
3.
CAREFULLY remove the HOT Automatic Vat Cleaner from the hanger bracket, and THOROUGHLY clean it in a
3 compartment sink.
4.
Proceed to paragraph B 1 page 42.
������� ������
������ �������
Page 41 of 61
������� ������
������� ����
������� ������
������ � ���������
������ ������
30A135
Need help?
Do you have a question about the PAR-3-HE and is the answer not in the manual?