INSTALLATION
12. Connect the remaining piece of duct to the ceiling grille and onto the fan using the duct tape provided.
NOTE: Make sure wherever possible to keep the duct running in a straight line as this will improve the performance of the fan.
13. Make the electrical connection as follows:
Wiring of Standard Switching Models FAN5375 / FAN5376 / FAN5377 / FAN5899 / FAN5900 (Diagram 2).
The fan can be connected to the light switch so that the fan will start when the light is switched on, or a dedicated fan switch (not supplied).
The fan should not be accessible to a person using either the shower or the bath.
Wiring of Timer Switching Models FAN2033 / FAN2034 / FAN2035 / FAN2036 (Diagram 3).
The fan can be connected to the light switch so that the fan will start when the light is switched on, or a dedicated fan switch (not supplied).
The fan should not be accessible to a person using either the shower or the bath.
NOTE: All wiring must be fi xed securely and the cable to the fan should be a minimum of 1mm
must comply with current regulations. This system should be installed by a registered electrician.
The timer mechanism supplied is a fully adjustable timer which is installed in the fl ush box. This means that the fan will run on for approx
0-20 minutes depending on settings (see diagram 2 for wiring instructions, and also instructions included with FAN2444 timer).
NOTE: There is an adjustable 0-5 minute delay time setting for switching the fan on.
Installation Instructions
enquiry@manrose.co.nz | www.manrose.co.nz
Specifi cations are subject to change without notice
2
in section in section. All wiring
Distributed by Simx Limited