To start/stop Comfort airflow operation

5.3.5 Powerful operation

To start/stop Powerful operation
FTXF20~42D5V1B + ATXF20~42D5V1B
Daikin room air conditioners
4D520466-13G – 2021.12
INFORMATION
Powerful and Comfort airflow operation CANNOT be used at the same time. The last
selected function takes priority. If the vertical automatic swing is selected, Comfort
airflow operation will be cancelled.
1 Press
to start.
Result: The flap position will change,
airflow rate is set to automatic.
Mode
Cooling/Drying
Heating
2 Press
to stop.
Result: The flap will return to the position from before the Comfort airflow mode;
disappears from the LCD.
This operation quickly maximizes the cooling/heating effect in any operation mode.
You can get the maximum capacity.
Mode
Cooling/Heating
Drying
Fan only
INFORMATION
Powerful operation CANNOT be used together with Econo and Comfort airflow
operation. The last selected function takes priority.
Powerful operation will NOT increase the capacity of the unit if it already operates at
maximum capacity.
1 Press
to start.
Result:
is displayed on the LCD. Powerful operation runs for 20 minutes;
after that, operation returns to the previously set mode.
is displayed on the LCD, and the
Position of flap...
Up
Down
Airflow rate
To maximize the cooling/heating
effect, the capacity of outdoor unit is
increased.
The airflow rate is fixed to the
maximum setting.
The temperature and airflow settings
CANNOT be changed.
The temperature setting is lowered by
2.5°C.
The airflow rate is slightly increased.
The airflow rate is fixed to the
maximum setting.