Intelligent Eye Operation; To Start/Stop Comfort And Intelligent Eye Operation; Powerful Operation; To Start/Stop Powerful Operation - Daikin Siesta ATXM20A2V1B Operation Manual

Hide thumbs Also See for Siesta ATXM20A2V1B:
Table of Contents

Advertisement

5.5.2

Intelligent eye operation

The system detects movement in the room and automatically adjusts
the airflow direction and temperature in order to avoid direct contact
with people. If no movement is detected for 20 minutes, the system
switches to energy saving operation:
About the Intelligent eye sensor
NOTICE
▪ Do NOT hit or push the Intelligent eye sensor. Doing so
may lead to malfunction.
▪ Do NOT place large objects near the Intelligent eye
sensor.
INFORMATION
Night set mode (OFF timer) CANNOT be used at the same
time with Intelligent eye operation.
▪ Detection sensitivity. Changes according to location, the number
of persons in the room, temperature range, etc.
▪ Detection mistakes. The sensor may mistakenly detect pets,
sunlight, moving curtains, etc.
5.5.3
To start/stop Comfort and Intelligent eye
operation
1 Press
one or more times.
Result: The setting will change as follows:
Display
+
Note: If there are people close to the front of the indoor unit or there
are too many people, use both operations at the same time.
2 To stop operation, press
from the LCD.
5.6

Powerful operation

This operation quickly maximizes the cooling/heating effect in any
operation mode. You can get the maximum capacity.
INFORMATION
Powerful operation CANNOT be used together with Econo,
Comfort airflow and Outdoor unit quiet operation. The last
selected function takes priority.
Powerful operation will NOT increase the capacity of the
unit if it already operates at maximum capacity.
5.6.1

To start/stop Powerful operation

1 Press
to start.
Result:
is displayed on the LCD. Powerful operation runs
for 20 minutes; after that, operation returns to the previously set
mode.
2 Press
to stop.
Result:
disappears from the LCD.
ATXM-A
Daikin room air conditioner
3P728539-4 – 2023.06
Operation
Comfort airflow
Intelligent eye
Comfort airflow and Intelligent eye
Both deactivated
until both symbols disappear
Note: Powerful operation can be set only when the unit is running. If
you press
or if you change operation mode, operation will be
cancelled;
disappears from the LCD.
5.7
Econo and Outdoor unit quiet
operation
5.7.1

Econo operation

This is a function which enables efficient operation by limiting the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.
INFORMATION
▪ Powerful and Econo operation CANNOT be used at the
same time. The last selected function takes priority.
▪ Econo operation reduces power consumption of the
outdoor unit by limiting the rotation speed of the
compressor. If power consumption is already low,
Econo operation will NOT further reduce power
consumption.
5.7.2

Outdoor unit quiet operation

Use Outdoor unit quiet operation when you want to decrease the
noise level of the outdoor unit. Example: At night.
INFORMATION
▪ Powerful and Outdoor unit quiet operation CANNOT be
used at the same time. The last selected function takes
priority.
▪ This function is only available in Automatic, Cooling,
and Heating operation.
▪ Outdoor unit quiet operation limits the rotation speed of
the compressor. If the rotation speed of compressor is
already low, Outdoor unit quiet operation will NOT
further reduce the compressor rotation speed.
5.7.3
To start/stop Econo and Outdoor unit
quiet operation
1 Press
one or more times.
Result: The setting will change as follows.
Display
+
2 To stop operation, press
from the LCD.
Note: Econo operation can be only set when the unit is running.
Pressing
cancels the setting and
Note:
remains on the LCD, even if you turn off the unit using
the wireless remote control or indoor unit ON/OFF switch.
5 Operation
Operation
Econo
Outdoor unit quiet
Econo and Outdoor unit quiet
Both deactivated
until both symbols disappear
disappears from the LCD.
Operation manual
9

Advertisement

Table of Contents
loading

Table of Contents