position and resume from this position after the linkage action finishes.
 The speed dome can be configured to resume the PTZ positions, focus and iris value.

3.5.3 Configuring Alarm Output

Purpose:
An alarm output is a configurable alarm output interface on the speed dome back box which can
connect and trigger another alarm device to operate.
Steps:
1. Enter the alarm output configuration submenu:
MAIN MENUS > DOME SETTINGS > ALARM OUTPUT
2. Click IRIS+ to edit the status of the alarm outputs. You can set the alarm output type as OPEN
(normally open) and CLOSE (normally closed).
There is 1 alarm output configurable; configuring the alarm output 2 will be invalid.
3. Move the cursor to DWELL TIME to set the duration of the alarm output signal. The configurable
rage is 0~60 seconds.
4. Link the alarm output to the configured alarm.
Steps:
(1) Enter MAIN MENUS > DOME SETTINGS > ALARM INPUT > ALARM SETTING and choose the
alarm number that you want to link the alarm output to.
(2) Move the cursor to ALARM OUTPUT and click IRIS+ to configure the alarm output to the
alarm. You can choose NONE to disable alarm outputs, choose 1 to active ALARM OUTPUT
1.
There is 1 alarm output configurable; configuring the alarm output 2 will be invalid.
ALARM OUTPUT
ALARM OUTPUT 1
DWELL TIME
ALARM OUTPUT 2
DWELL TIME
BACK
Figure 3-21 Configure the Alarm Output
CLOSE
2
OPEN
0
EXIT