Configuring Image Parameters; Configuring Camera Parameters - HIKVISION DS-2AE5232TI-A User Manual

Hd-tvi speed dome
Table of Contents

Advertisement

User Manual of HD-TVI Speed Dome
You can set 485 CHECK as ON or AUTO for automatic RS-485 configuration diagnosis. If the
configuration is incorrect, an alert will be received; if you set the value as AUTO, it will
automatically stop the diagnosis when no errors exist.
 Power Memory Settings
The dome can resume its previous PTZ status after it restarted from a power-off when it stops at a
position longer than the predefined time. You can set the memory time to 10S, 30S, 60S, 180S, and
300S.
 Coaxial Control
The Coaxial transmission function can be enabled to transmit the RS485 signal along with the video
signal via the BNC cable. If the connected encoding device supports the Coaxial transmission as well,
the RS485 cable will not be necessary.
Steps:
1) Enable the Coaxial control function by setting the option of COAXIAL CONTROL to ON.
2) Select the Coaxial control protocol, there are HIK-C, PELCO-C and AUTO selectable.
The transmission protocol of the connected encoding device should be set the same as the
speed dome to support the coaxial transmission.

3.3 Configuring Image Parameters

3.3.3 Configuring Camera Parameters

Purpose:
You can set the camera parameters including focus, shutter speed, iris, etc.
Enter the camera parameters settings menu:
MAIN MENUS > DOME SETTINGS >CAMERA SETTINGS
CAMERA
FOCUS
ZOOM LIMIT
ZOOM SPEED
HIGH
SLOW SHUTTER
DAY/NIGHT
AUTO
D/N SENSITIVITY
SHARPNESS
BACK
EXIT
CAMERA
AF
BLC/WDR
22
BLC LEVEL
EXP MODE
ON
IRIS
SHUTTER
1
GAIN
8
EXPOSURE COMP
BACK
OFF
N/A
AUTO
10
50
N/A
7
EXIT