HIKVISION DS-2AE5232TI-A User Manual page 16

Hd-tvi speed dome
Table of Contents

Advertisement

User Manual of HD-TVI Speed Dome
 Dome address settings
To Set the Soft Address of the Speed Dome
If the SET SOFT ADDR is set as ON, the soft address is the valid address for connecting the speed
dome. The selectable soft address range is from 1 to 255;
If the SET SOFT ADDR is set as OFF, the hard address set by the DIP switch is the valid address of the
speed dome.
 Before you set the soft address of the speed dome, you need to confirm that it is within the
control range of the control device (e.g. the DVR).
 After you enable/disable the soft address, the speed dome will reboot automatically to activate
the settings.
To Set the Broadcast Address of the Speed Dome
When the BROADCAST ADDR is set to ON, the control device with address 0 is capable of
controlling all domes connected to it.
 Soft Baud Rate Settings
If the SET SOFT BAUD is set as ON, the soft baud rate is the valid baud rate for the speed dome,
with 2400, 4800, 9600 and 19200 selectable.
If the SET SOFT BAUD is set as OFF, the baud rate should be set by the DIP switch.
After you enable/disable the soft baud rate, the speed dome will reboot automatically to
activate the settings.
 PELCO Checksum
The PELCO CHECKSUM is used for Pelco-P and Pelco-D protocols. If the video turns to slack or
uncontrollable, you can set the PELCO CHECKSUM as ON to improve the video quality.
 System Time Configuration
Steps:
(1) Move the cursor to SYS TIME using the direction buttons and click IRIS+ to enter.
(2) Click the left/right direction buttons to position the cursor on the specific item
(year/month/day or hour/minute/second) of which you want to change the value.
(3) Click the up/down direction buttons to increase/decrease the value.
(4) Click IRIS+ button to confirm the settings and exit.