3 Mechanical Installation
3.1 Installation Condition
3.1.1 Environment temperature: -40 to 85℃.
3.1.2 Operating temperature: -40 to 85℃.
3.1.3 The maximum altitude of the PV module is designed: 2000m.
3.1.4 Tilt Angle selection: The installation should be facing north in the southern hemisphere and facing
south in the northern hemisphere.
3.1.5 To maintain the modules' Class C fire rating, the fire class of the roof and building materials should
higher than Class C. The fire rating of this module is valid only when mounted in the manner
specified in the mechanical mounting instructions.
3.1.6 Raise the distance when installation requirement is greater than or equal to 0.3 m. Module
installation use appropriate installation angle, refer to the following Table 3.
This document is only for internal use of JINNENG CLEAN ENERGY TECHNOLOGY LTD, and shall not be published or
copied without permission of the company.
Do not place the module in the combustible gas
easy generation or congregate.
In the process of moving module, do not grab
junction box and cable, should contact the module
frame for handling.
In any case, please don't trample modules.
To protect the glass is damaged, please do not
place heavy objects on the module or throwing have
damage to any of the items out of modules.
Careful handling, avoid knock against. Improper
handling and placement, may cause module of glass
breakage and loss of performance, which affects the
output.