9 - REGOLAZIONE ELETTRONICA
Indirizzo
Address
1
Stato uscita digitale 1 / DO1 status
2
Stato uscita digitale 2 / DO2 status
3
Stato uscita digitale 3 / DO3 status
4
Stato uscita digitale 4 / DO4 status
5
Stato uscita digitale 5 / DO5 status
6
Stato uscita digitale 6 / DO6 status
7
Stato uscita digitale 7 / DO7 status
8
Stato unità / Unit status
9
Allarme / Alarm
10
On/Off da supervisore /Supervisor on/off
11
On/off remoto / Remote On/Off
12
Pressostato filtri / Filter Pressure switch
13
Allarme sonda su AI1 / Probe alarm AI1
14
Allarme sonda su AI2 / Probe alarm AI2
15
Allarme sonda su AI3 / Probe alarm AI3
16
Allarme sonda su AI4 / Probe alarm AI4
17
Allarme sonda su AI5 / Probe alarm AI5
18
Allarme sonda su AI6 / Probe alarm AI6
19
Allarme sonda su AI7 / Probe alarm AI7
20
Stato DI1 / DI1 Status
21
Stato DI2 / DI2 Status
22
Stato DI3 / DI3 Status
23
Stato DI4 / DI4 Status
24
Stato DI5 / DI5 Status
25
Stato DI6 / DI6 Status
26
Stato DI7 / DI7 Status
27
Reset allarmi Alarm / Reset alarm command
28
Cumulativo Allarme Inverter / Inverter Alarm
29
Allarme Inverter Offline /Inverter offline Alarm
30
Allarme Alta pressione/ High pressure alarm
31
Allarme Bassa pressione/ Low oressure alarm
32
Allarme valvola espansione elettronica / EVD Alarm
33
Allarme Klixon / Klixon Alarm
34
Allarme Inverter / Generic Inverter Alarm
35
Allarme da DI / Alarm from external device (DI)
Allarme Massima temperatura Driver / Inverter high
36
temperature alarm
Allarme Aria esterna troppo alta /External air temperature
37
too high
Allarme Aria esterna troppo Bessa /External air
38
temperature too low
Abilita Allarme massima aria esterna /Enable External air
39
temperature Alarm
Abilita Allarme minima aria esterna /Enable External air
40
temperature too low
Abilita Allarme Sovratemperatura Driver /Enable high
41
inverter temperature alarm
Warning temperatura aria esterna massima /Warning
42
external air temperature too high
Warning temperatura aria esterna minima /Warning
43
external air temperature too low
-
pag.37 - Manuale di installazione, Uso e Manutenzione - Installation, Use and Maintenance Manual
Variabili digitali / Digital variables
Nome / Name
Accesso
UM Default Range
Access
R
R
R
R
R
R
R
R
R
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
-
R/W
R
R
R
-
R
-
R
R
R
R
R
R
R
R/W
R/W
R/W
R
R
-
-
36
9 - ELECTRONIC CONTROL
Descrizione / Description
Actual value of digital output 1 (inverter enable)
Actual value of digital output 2 (addtional electric
post heater)
Actual value of digital output 3 (fan on)
Actual value of digital output 4 (electric pre heater)
Actual value of digital output 5 (reverse valve)
Actual value of digital output 6 (alarm)
Actual value of digital output 7 (on/off I/O dampers)
0= off, 1=on
Alarm summary
Unit on from supervisor
Status of Remote on/off digital input
Status of filter pressure switch digital input
Probe broken or disconnected AI1(external
temperature)
Probe broken or disconnected AI2 (room/return
temperature)
Probe broken or disconnected AI3(evaporation
temperature)
Probe broken or disconnected AI4(supply
temperature)
Probe broken or disconnected AI5(CO2 probe)
Probe broken or disconnected AI6 (evaporation
pressure)
Probe broken or disconnected AI7 (condensation
pressure)
Actual Value of digital input 1 (filter switch)
Actual Value of digital input 2 (remote on/off)
Actual Value of digital input 3 (compressor klixon)
Actual Value of digital input 4(not used)
Actual Value of digital input 5 (not connected)
Actual Value of digital input 6 (low pressure switch)
Actual Value of digital input 7 (external alarm)
-
Inverter alarm summary
-
-
Generic Inverter Alarm
If selected when external air temperature is too
high compressor is stopped
If selected when external air temperature is too low
compressor is stopped
If selected when inverter temperature is too high
compressor is stopped
-