Instructions
Coded function system
Notes
This instruction manual is for the coded function system.
To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use
of this product, we recommend that you study this manual thoroughly before operating this
Optical Microscope Accessory
product, and always keep this manual at hand when operating this product.
Retain this instruction manual in an easily accessible place near the work desk for future
reference.
For details of products included in the configuration of this system, see page 4.

Advertisement

Table of Contents
loading

Summary of Contents for Olympus U-CBS

  • Page 1 Instructions Coded function system Notes This instruction manual is for the coded function system. To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of this product, we recommend that you study this manual thoroughly before operating this Optical Microscope Accessory product, and always keep this manual at hand when operating this product.
  • Page 2 In accordance with European Directive on Waste Electrical and Electronic Equipment, this symbol indicates that the product must not be disposed of as unsorted municipal waste, but should be collected separately. Refer to your local Olympus distributor in EU for return and/or collection systems available in your country. For Korea only 이...
  • Page 3: Table Of Contents

    Contents IMPORTANT - - ....1 Be sure to read this section for safe use of the equipment. 1 Nomenclature of each part ......................3 2 System diagram ............................4 3 Layout of the cables ..........................6 Combining with the microscope frame (BX53F2) and U-IFRES ............7 Combining with the microscope frame (BX43F) and U-IFRES .............8 Combining with the microscope frame (BX43F) ....................9 4 Information readout / External transmission ...............10...
  • Page 4: Important

    Safety precautions · Before connecting the cables, be sure to set the POWER switch of the control box for coded function (U-CBS) to OFF (out position). · For safety, always use the provided AC adapter only. · Keep the cables away from the lamp housings (halogen bulb, etc.) that become hot and the surroundings.
  • Page 5 (depressed position). Otherwise, malfunction may result. · Never disassemble any part of the product. Otherwise, failure may result. · Before disposing of this product, be sure to follow the regulations and rules of your local government. Contact Olympus for any questions.
  • Page 6: Nomenclature Of Each Part

    Coded function system Nomenclature of each part Control box for coded function U-CBS Microscope frame hanger (top) RS-232C connector Connector for coded revolving nosepiece Connector for BX3-CBM Connector for coded illuminator Connector for hand switch For external EXPOSE button of...
  • Page 7: System Diagram

    If a non-specified unit is connected, the performance of the entire system cannot be guaranteed. · Before connecting the cables, be sure to set the POWER switch of U-CBS to OFF (out position). Insert the cables securely to connectors paying attention to their shapes. If the connector is provided with clamping screws, be sure to tighten them.
  • Page 8 U-IFRES or the coded revolving nosepiece, align marks b in the same manner. Note 3) Hang U-CBS c on the hangers d on the back side of the microscope frame. Note 4) When connecting the microscope digital camera to U-CBS to use...
  • Page 9: Layout Of The Cables

    The cables of units can be laid out easily by attaching the cable holders on the back side of the microscope frame. The cable holders are provided with following units. · Control box for coded function (U-CBS): 6 pieces · Coded revolving nosepiece: 2 pieces On page 7 and after, the positions to attach cable holders and the cable layout are described for each microscope frame.
  • Page 10: Combining With The Microscope Frame (Bx53F2) And U-Ifres

    Coded function system Combining with the microscope frame (BX53F2) and U-IFRES Coded revolving nosepiece Coded illuminator U-IFRES Cable holder* RS-232C cable Align with the upper left corner of the label. About 85 mm Cable holder** Align with the height of the edge between the back side and under back side and under...
  • Page 11: Combining With The Microscope Frame (Bx43F) And U-Ifres

    Coded function system Combining with the microscope frame (BX43F) and U-IFRES Coded revolving nosepiece Coded illuminator U-IFRES RS-232C cable Cable holder* Align with the upper left corner of the label. Cable holder** Align with the upper right corner of the label. Hand switch** About 63 mm Velcro tape...
  • Page 12: Combining With The Microscope Frame (Bx43F)

    Coded function system Combining with the microscope frame (BX43F) Coded illuminator Coded revolving nosepiece Cable holder* RS-232C cable Align with the upper left corner of the label. Cable holder** Align with the upper right corner of the label. Hand switch** About 63 mm Velcro tape (provided with hand switch)
  • Page 13: Information Readout / External Transmission

    Coded function system Information readout / External transmission This system configuration enables to acquire the information of following units. · Information of the hole position (objective position) of the revolving nosepiece · Information of the mirror unit position of the coded illuminator The acquired information is transmitted to PC or the microscope digital camera through the RS-232C cable to enable following functions.
  • Page 14 · Be careful, if the connector of the coded revolving nosepiece is not connected to U-CBS, the hand switch does not function. If the cable for the hand switch disturbs your operation, bundle...
  • Page 15: Specifications

    Specifications Control box for coded function Dimension 37.8 (W) x 30.6 (D) x 163 (H) mm Weight 0.5 kg (including AC adapter 0.17 kg) U-CBS Rating 5 V / 0.5 A Hand switch Dimension Body: Ø25.4 x 35.5 (H) mm Attaching plate: Ø32 x 1 (H) mm...
  • Page 16 Manufactured by Shinjuku Monolith, 2-3-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo 163-0914, Japan Distributed by AX9442 01...