Download Print this page
Olympus U-5RES-ESD Instructions Manual
Olympus U-5RES-ESD Instructions Manual

Olympus U-5RES-ESD Instructions Manual

Coded function system

Advertisement

U-5RES-ESD
U-D5BDRES-ESD
U-D7RES
BX3-RFAS
U-HSEXP
U-CBS
This instruction manual is for the Olympus Coded Function System. To ensure the safety, obtain optimum
performance and to familiarize yourself fully with the use of this system, we recommend that you
study this manual and the manuals of units used in combination with this system thoroughly before
operating the system.
Retain this instruction manual in an easily accessible place near the work desk for future reference.
CODED FUNCTION SYSTEM
INSTRUCTIONS
A X 7 8 7 7

Advertisement

loading
Need help?

Need help?

Do you have a question about the U-5RES-ESD and is the answer not in the manual?

Questions and answers

Summary of Contents for Olympus U-5RES-ESD

  • Page 1 U-CBS CODED FUNCTION SYSTEM This instruction manual is for the Olympus Coded Function System. To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of this system, we recommend that you study this manual and the manuals of units used in combination with this system thoroughly before operating the system.
  • Page 2 In accordance with European Directive 2002/96/EC on Waste Electrical and Electronic Equipment, this symbol indicates that the product must not be disposed of as unsorted municipal waste, but should be collected separately. Refer to your local Olympus distributor in EU for return and/or collection systems available in your country.
  • Page 3: Table Of Contents

    BX43 (System with LED Lamp Housing) ................................7 BX43 (System with Halogen Lamp Socket)..............................8 BX53 System ................................................. 9 * When using Industrial Microscope Frames such as BX41M-LED, BX51/51M, GX51/71 or STM6, refer to manual “U-5RES-ESD/U-D5BDRES-ESD” for detailed installation instructions. 4 READOUT/EXTERNAL TRANSMISSION OF CODED INFORMATION...
  • Page 4: Important - Be Sure To Read This Section For Safe Use Of The Equipment

    This system enables to read coded information from the Coded Fluorescence Illuminator (BX3-RFAS) and the Coded Revolving Nosepiece (U-D7RES, U-5RES-ESD, U-D5BD5RES-ESD), and to transmit the information externally. To ensure the safety, refer to this manual and the manuals of units used in combination with this system thoroughly before operating the system.
  • Page 5 CODED FUNCTION SYSTEM Getting Ready 1. This system is composed of precision instruments. Handle it with care and connect cables gently to avoid subjecting it to sudden or severe impact. Besides, this system is not waterproof. 2. Do not use the system where it is subjected to direct sunlight, high temperature and humidity, dust or vibrations. 3.
  • Page 6: Connector Nomenclature

    CONNECTOR NOMENCLATURE Control Box for Coded Function U-CBS Microscope frame hangers (top/bottom) U-D7RES U-5RES-ESD U-D5BDRES-ESD connector RS-232C connector BX3-RFAS connector Option connector The U-CBM can be connected. U-HSEXP connector For the external DP21 exposure button. POWER switch ON: Depressed position.
  • Page 7: System Chart

    The connectors of the U-CBS are sealed with dust covers. Remove the dust covers only from the connectors you want to connect cables. · Be sure to connect the module designated by Olympus to each connector. If a non-designated module is connected, the performance of the entire system cannot be guaranteed.
  • Page 8 RS-232C cable specifications D-sub 9-pin (female) D-sub 9-pin (female) Note 2) When connecting a cable to the BX3-RFAS, U-D7RES, U-5RES-ESD or U-D5BDRES-ESD connector, align the t markings @ on the connectors of the cable and the U-CBS (Fig. 1). Note 3) Hang the U-CBS control box 2 on the hangers 3 on the rear of the Fig.
  • Page 9: Cable Distributions

    U-CBS control box ..x6 U-D7RES coded revolving nosepiece ..x2 U-5RES-ESD coded revolving nosepiece ..x4 U-D5BDRES-ESD coded revolving nosepiece ..x4 U-LS30AD adapter ..x1 · In the subsequent pages, the positions for attaching the cable holders and the method of cable distribution will be described for each microscope system.
  • Page 10: Bx43 (System With Led Lamp Housing)

    BX43 (System with LED Lamp Housing U-LHLEDC) BX3-RFAS cable U-D7RES cable Use 6 cable holders. RS-232C cable Align with the top right Align with the top left corner of the label. corner of the label. U-HSEXP cable for U-HSEXP cable for left side installation right side installation Banding band...
  • Page 11: Bx43 (System With Halogen Lamp Socket)

    CODED FUNCTION SYSTEM BX43 (System with Halogen Lamp Socket U-LSADP + U-LS30-5) BX3-RFAS cable U-D7RES cable U-HSEXP cable for right side installation RS-232C cable Use 6 cable holders. Align with the top right corner of the label. Align with the top left corner of the label.
  • Page 12: Bx53 System

    BX53 System U-D7RES cable BX3-RFAS cable Approx. 10 mm Align with the top left corner of the label. RS-232C cable U-HSEXP cable for Align with the top right right side installation corner of the label. Align with the top of the lamp housing connector.
  • Page 13: Readout/External Transmission Of Coded Information

    READOUT/EXTERNAL TRANSMISSION OF CODED INFORMATION } This system makes it possible to acquire the information on the objective positions of the coded revolving nosepiece (U-D7RES, U-5RES-ESD, U-D5BDRES-ESD) and that on the mirror unit positions of the coded fluorescence illuminator (BX3-RFAS).
  • Page 14 · PC · Mobile phone · Clock/watch · Credit card · Bank card · Floppy disk, etc. } Unless the coded revolving nosepiece (U-D7RES, U-5RES-ESD, U- D5BDRES-ESD) is connected to the U-CBS, the U-HSEXP does not function. So be careful.
  • Page 16 Shinjuku Monolith, 3-1, Nishi Shinjuku 2-chome, Shinjuku-ku, Tokyo, Japan Wendenstrasse 14-18, 20097 Hamburg, Germany 3500 Corporate Parkway, Center Valley, Pennsylvania 18034-0610, U.S.A. 491B River Valley Road, #12-01/04 Valley Point Office Tower, Singapore 248373 31 Gilby Road, Mount Waverley, VIC., 3149, Melbourne, Australia 5301 Blue Lagoon Drive, Suite 290 Miami, FL 33126, U.S.A.

This manual is also suitable for:

U-d5bdres-esdU-d7resBx3-rfasU-hsexpU-cbs