Troubleshooting - Alpha ESS SMILE-T10-HV-INV User Manual

Energy storage system
Table of Contents

Advertisement

Your Smart Energy

7.2 Troubleshooting

7.2.1 Inverter Error Troubleshooting
Error
Error description
No.
100000
Grid_OVP
100001
Grid_UVP
100002
Grid_OFP
100003
Grid_UFP
100005
BUS_OVP1
100006
BUS_OVP2
100007
Insulation_fault
100008
GFCI_fault
100009
Leakage current test failure
100010
Grid_relay_fault
100011
Over_Temperature
100014
M_S_com_fault
100038
Output_DC_over_current
100043
Output_overload
100044
APU_UVP
100046
DC_Input_Disturbance
100047
Grid disturbance
100048
Grid_unbalance
100049
Frequency_jitter
100050
Grid_overcurrent
100051
Grid_current_track_fault
100052
Backup_ovp
100053
Dc_bus_unbalancevolt
100054
Dc_bus_undervolt
100055
Dc_bus_unbalancevolt2
100056
IGBT_over_current
100057
Grid_disturbance2
100058
AFCI_check_protect
___________________________________________________________________
Page 34 of 43
Solution
1. Check whether Grid is abnormal.
2. Confirm whether the grid cable connection
is normal.
3. Restart inverter and ensure whether the
fault is existing.
Restart inverter and ensure whether the fault
is existing.
1.Check whether PV cable connection is
reliable.
2.Check whether PV cable is damaged.
Restart inverter and ensure whether the fault
is existing.
1. Check whether the environment around
inverter is with poor heat dissipation.
2. Confirm whether inverter installation meet
the installation requirements.
Restart System and ensure whether the fault
is existing.
1. Check whether Backup load is overload.
2. Restart inverter and confirm whether the
fault is existing.
Restart System and ensure whether the fault
is existing.
1. Check whether Grid is abnormal.
2. Confirm connection of gird cable is nor-
mal.
3. Restart inverter and ensure whether the
fault is existing.
Restart inverter and ensure whether the fault
is existing.
1. Check whether Backup port cable is nor-
mal.
2. Restart inverter and confirm whether the
fault is existing.
Restart inverter and ensure whether the fault
is existing.
Restart inverter and ensure whether the fault
is existing.
1. Confirm whether Grid is distorted severely.
2.Check whether PV cable connection is reli-
able.
1.Check whether PV cable connection is
reliable.
Alpha ESS Co., Ltd.

Hide quick links:

Advertisement

Table of Contents
loading