Table of Contents

Advertisement

ITL NV9

The NV9 validator has been designed to minimize any performance variation over time. Much of
this is achieved by careful hardware and software design.
However, depending upon the environment the NV9 may at some time require cleaning, belt
changing or note path clearing.
Periodical Cleaning
ATTENTION:
Do NOT use solvent based cleaners such as alcohol, petrol, methylated spirits, white
spirit or PCB cleaner.
This will result in permanent damage to the validator - only use a mild detergent.
To clean, slide the red release catch on the end of the NV9 Validator to the left, to open the note
path. The note path and lozenge are now exposed for cleaning.
Carefully wipe the surfaces with a soft lint free cloth that has been dampened with a water and
mild detergent solution (i.e. household washing up liquid). Take particular care around all the
sensor lenses, ensuring they are clean and dry.
ATTENTION:
When cleaning the recessed front sensors, use a small soft brush or cotton wool bud.
If a lens has become badly scratched do not attempt to polish it. Contact ITL for further advice,
as there may be damage to the optical properties of the lens.
Manual Go4Platin_en COMPLETE.docx / BG