4. Please use a cotton swab or lint-free cloth and a cleaning solution -- a mix of water and
up to 50 % Iso Propyl Alcohol (IPA) is recommended.
o DO NOT use more than 50 % IPA. NEVER use solvent--based cleaning agents, such
as pure alcohol, petrol, methylated spirit or white spirit on this product as the unit
will be severely damaged.
o Using the Cotton swab or cloth dipped in the cleaning solution - carefully clean all
sensors and plastic windows using light force only.
o Continue with swab to clean note path, all rollers and belts.
o Use an additional swab or cloth to dry area cleaned, if required.
o Reconnect host loom.
5. To refit the currency validator to the faceplate simply, insert the two black locating legs
into the holes and push fully until you hear a loud clipping sound.
6. Pull fully on the validator to ensure correct fitment.