Relay Output; Combus Connection - DSC MAXSYS PC4020CF System Manual

Hide thumbs Also See for MAXSYS PC4020CF:
Table of Contents

Advertisement

PGM CONNECTIONS
LED INDICATOR
680 Ω
LED
INDICATOR
RESISTOR
(TYPICAL VALUE)
SW AUX CONNECTION
SENSOR RESET FOR SMOKE DETECTOR
IN
OUT
RED
ALARM
CONTACT
BLK
OUT
IN
Notes: 5600 Ω applies only to the PC4020
main board. Use 2200 Ω (red, red, red, gold)
for the expansion modules.
Do NOT connect Fire zones or Links Supervisory
zone for Double EOL resistors.
MULTIPLE SMOKE DETECTORS ON ONE ZONE
MULTIPLE RESIDENTIAL SMOKE DETECTORS ON ONE ZONE
BELL LOOP
700 mA MAX
IN
OUT
ALARM
CONTACT
IN
OUT
4-WIRE SMOKE
DETECTOR POWER
11 V
400 mA MAX
DC
Note: Do NOT connect Fire zones or Links
Supervisory zone for Double EOL resistors.

COMBUS CONNECTION

Notes:
1. The toroid must be installed as shown to reduce the possibility of
electromagnetic interference.
2. If the toroid cannot accomodate the number of cables to be run to the
control, then they should be spliced colour to colour into a single cable
before reaching the toroid.

RELAY OUTPUT

RED
BLK
DSC
RM-1
WHT
YEL GRN
COM N.C.
N.O.
ZONE INPUT MUST BE
PROGRAMMED FOR FIRE
TO ANY
ALARM INPUT: STANDARD FIRE
"COM" TERMINAL
DELAYED FIRE
AUTO VERIFY FIRE
TO ANY ZONE
SW AUX PROGRAMMED FOR
"Z" TERMINAL
SENSOR RESET
WHT
POWER
SUPERVISORY
RELAY
(DSC RM-1)
GRN
5600 Ω
END OF LINE RESISTOR
(EOLR-2)
TO ZONE "Z"
ZONE INPUT MUST BE
TERMINAL
PROGRAMMED FOR FIRE
PROGRAMMED
ALARM INPUT: STANDARD FIRE
FOR "FIRE"
DELAYED FIRE
AUTO VERIFY FIRE
TO ANY "COM"
MINIMUM 18 AWG WIRING IS REQUIRED
TERMINAL
FOR RESIDENTIAL FIRE ALARM SYSTEMS
WHT
IN
OUT
RED
SUPERVISORY
ALARM
CONTACT
(DSC RM-1)
BLK
IN
OUT
GRN
5600 Ω
END OF LINE RESISTOR
(EOLR-2)
firealarmresources.com
Loop
Maximum wire run to EOL relay in feet/meters
Current
AWG14
AWG16
mA
50
2750/838
1740/530
100
1375/419
870/265
200
435/132
690/210
300
460/140
290/88
400
345/105
215/65
Bell
Maximum wire run to EOL resistor in feet/meters
Current
AWG14
AWG16
mA
50
2750/838
1740/530
100
1375/419
870/265
200
690/210
435/132
300
460/140
290/88
400
345/105
215/65
500
275/83
170/52
600
230/70
140/43
700
195/59
125/38
Wire
Maximum Run to End of Line Resistor
Gauge
AWG14
AWG16
AWG18
AWG19
AWG20
AWG21
AWG22
POWER
RELAY
11
AWG18
AWG19
AWG22
1090/332
869/264
433/131
545/166
435/132
217/66
270/82
217/66
108/33
180/55
144/33
144/43
135/41
108/33
54/16
AWG18
AWG19
AWG22
1090/332
869/264
433/131
545/166
435/132
217/66
270/82
217/66
108/33
180/55
144/33
144/43
135/41
108/33
54/16
105/32
86/26
43/13
90/27
72/22
36/11
80/24
62/19
30/9
(feet / meters)
15500 / 4724
9740 / 2968
6120 / 1865
4860 / 1481
3840 / 1170
3060 / 932
2420 / 737