PC4400 v2.0 • Installation Guide
WARNING: This manual contains information on limitations
regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire
manual should be carefully read.
firealarmresources.com

Advertisement

Table of Contents
loading

Summary of Contents for DSC MAXSYS PC4400

  • Page 1 ® PC4400 v2.0 • Installation Guide WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. firealarmresources.com...
  • Page 2 If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of time. Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may Any products returned to DSC which have the Installer’s Lockout option enabled and exhibit be difficult to detect.
  • Page 3: Table Of Contents

    Introduction ......1 Specifications ......1 PC4400 connected to a serial printer .
  • Page 4: Introduction

    I n t r o d u c t i o n Table of Contents Introduction The PC4400 module adds serial printer or DVAC com- Introduction ......1 munications capability to a MAXSYS PC4010 or PC4020 Specifications .
  • Page 5: Pc4400 Hookup Diagram

    PC4400 Hookup Diagram Applying Power After all wiring is completed, apply power to the control panel. Connect the battery leads to the battery, then connect the AC transformer. For more information on control panel power specifications, see the control panel Installation Manual. NOTE: Do not connect the power until all wiring is complete.
  • Page 6: Enrolling The Module

    E n r o l l i n g t h e M o d u l e Enrolling the Module ID Code Option This is the ID code the PC4400 module will use for Once all wiring is complete, you must enroll the module: DVAC communications.
  • Page 7 The following is a list of the default DVAC reporting and identifier codes: Rep # Title Printed Message 0000 - 007F Zone Alarms/Restore 001 - 128 (See Zone Events Section) 0080 - 00FF Zone Troubles/Restore 001 - 128 (See Zone Events Section) 0100 - 017F Zone Faults/Restore 001 - 128...
  • Page 8 5 . P r o g r a m m i n g t h e M o d u l e 02EE - 032D Wireless Zone Supervisory 18/98 151 - 214 Supervi 032E - 0335 Partition Police (1 - 8) 19/99 001 - 008 Burglary Verified...
  • Page 9: Default Dvac

    The list below shows the new zone types that apply to the PC40x0 v3.0 only. Zone Type FB: Printer MSG Interior Delay Interior Waterflow Fire Fire Supervisory Sprinkler Default DVAC System Area, then Communicator, then Reporting Codes). Ref. # [00080102] This command will restore the PC4400 programming •...
  • Page 10: Programming Worksheets

    Programming Worksheets Baud Rate REFERENCE # [000800] 1200 I _ ______I I _ ______ I I _ ______I 2400 4800 I _ ______I I _ ______ I DVAC Options REFERENCE # [00080100] ID Code Default = FF (Valid entries 01-FF) I _ ______I _ _______I All Call Select Default = FF...
  • Page 11: Dvac Identifiers

    DVAC Identifiers REFERENCE # [00080101] Zone X Alarm/Restore Rep # Rep # Rep # 0000 Zn 1 Alm/Rst 002B Zn 44 Alm/Rst 0056 Zn 87 Alm/Rst I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ______I _ _______I I _ ___ ___I _ _______I _ ______I I _ ______I _ _______I I _ ______I _ _______I _ ______I 0001 Zn 2 Alm/Rst 002C Zn 45 Alm/Rst...
  • Page 12: Dvac Identifiers

    P r o g r a m m i n g W o r k s h e e t s DVAC Identifiers REFERENCE #[00080101] Zone X Trouble/Restore Rep # Rep # Rep # 0080 Zn 1 Trb/Rst 00AB Zn 44 Trb/Rst 00D6 Zn 87 Trb/Rst I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ____ __I _ _______I I _ ______I _ _______I _ ______I...
  • Page 13: Zone X Fault/Restore

    Zone X Fault/Restore Rep # Rep # Rep # 0100 Zn 1 Ft/Rst 012B Zn 44 Ft/Rst 0156 Zn 87 Ft/Rst I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ______I _ _______I I _ ___ ___I _ _______I _ ______I I _ ______I _ _______I I _ ______I _ _______I _ ______I 0101 Zn 2 Ft/Rst 012C Zn 45 Ft/Rst...
  • Page 14: Module Tamper/Restore

    P r o g r a m m i n g W o r k s h e e t s Module Tamper/Restore Rep # Rep # Rep # 0188 LCD4500Md1 0193 LCD4500Md12 019E PC41XXMd6 I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ____ __I _ _______I I _ ______I _ _______I _ ______I I _ ______I _ _ ______I I _ ______I _ _______I _ ______I 0189 LCD4500Md2...
  • Page 15: Openings And Closings By User

    Openings and Closings by User Rep # Rep # Rep # 01CE O/C User 001 01F9 O/C User 044 0224 O/C User 087 I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ______I _ _______I I _ ___ ___I _ _______I _ ______I I _ ______I _ _______I I _ ______I _ _______I _ ______I 01CF O/C User 002 01FA O/C User 045...
  • Page 16: Miscellaneous Openings And Closings

    P r o g r a m m i n g W o r k s h e e t s Miscellaneous Openings and Closings Rep # Rep # Rep # 024E Quick Arm 0251 Auto Arm 0254-0256 For future use I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ____ __I _ _______I I _ ______I _ _______I _ ______I 024F Partial Closing...
  • Page 17: Wireless - Low Batter

    Wireless – Low Battery Rep # Rep # Rep # 02AE Zn 01 low batt 02C4 Zn 23 low batt 02DA Zn 45 low batt I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ______I _ _______I I _ ___ ___I _ _______I _ ______I I _ ______I _ _______I I _ ______I _ _______I _ ______I 02AF Zn 02 low batt 02C5 Zn 24 low batt...
  • Page 18: Dvac Identifiers

    DVAC Identifiers Function Bytes For alarm reports, bit number 7 of the function byte determines the status of the each printed event. Alarm Function Bytes In the following list, there are two entries for each event in the Function Byte column. The first number corresponds to an alarm;...
  • Page 19: Bypass Function Bytes

    Bypass Function Bytes In the following list, there are two entries for each event in the Function Byte column. The first number corresponds to the bypassing of a zone; the second corresponds to the unbypassing. Each event will thus be printed in one of two ways. For example: Burglar Byp ZnXXX...
  • Page 20: Miscellaneous Function Bytes

    D V A C I d e n t i f i e r s Miscellaneous Function Bytes Function Byte Printer Message Computer Message 78/F8 By User 000-999 No transmission 79/F9 Control Act/Rst Pt000-999 RC/RO 000-999 7A/FA Service Req/Req Zn000-999 YX/YX 000-999 7B/FB Dealer Id/Id 000-999...
  • Page 21 ©2001 Digital Security Controls Ltd. Toronto, Canada www.dsc.com • 1-800-387-3630 Printed in Canada 29002039 R003 firealarmresources.com...