Page 1
® PC4400 v2.0 • Installation Guide WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. firealarmresources.com...
Page 2
If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of time. Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may Any products returned to DSC which have the Installer’s Lockout option enabled and exhibit be difficult to detect.
I n t r o d u c t i o n Table of Contents Introduction The PC4400 module adds serial printer or DVAC com- Introduction ......1 munications capability to a MAXSYS PC4010 or PC4020 Specifications .
PC4400 Hookup Diagram Applying Power After all wiring is completed, apply power to the control panel. Connect the battery leads to the battery, then connect the AC transformer. For more information on control panel power specifications, see the control panel Installation Manual. NOTE: Do not connect the power until all wiring is complete.
E n r o l l i n g t h e M o d u l e Enrolling the Module ID Code Option This is the ID code the PC4400 module will use for Once all wiring is complete, you must enroll the module: DVAC communications.
Page 7
The following is a list of the default DVAC reporting and identifier codes: Rep # Title Printed Message 0000 - 007F Zone Alarms/Restore 001 - 128 (See Zone Events Section) 0080 - 00FF Zone Troubles/Restore 001 - 128 (See Zone Events Section) 0100 - 017F Zone Faults/Restore 001 - 128...
Page 8
5 . P r o g r a m m i n g t h e M o d u l e 02EE - 032D Wireless Zone Supervisory 18/98 151 - 214 Supervi 032E - 0335 Partition Police (1 - 8) 19/99 001 - 008 Burglary Verified...
The list below shows the new zone types that apply to the PC40x0 v3.0 only. Zone Type FB: Printer MSG Interior Delay Interior Waterflow Fire Fire Supervisory Sprinkler Default DVAC System Area, then Communicator, then Reporting Codes). Ref. # [00080102] This command will restore the PC4400 programming •...
P r o g r a m m i n g W o r k s h e e t s DVAC Identifiers REFERENCE #[00080101] Zone X Trouble/Restore Rep # Rep # Rep # 0080 Zn 1 Trb/Rst 00AB Zn 44 Trb/Rst 00D6 Zn 87 Trb/Rst I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ____ __I _ _______I I _ ______I _ _______I _ ______I...
P r o g r a m m i n g W o r k s h e e t s Module Tamper/Restore Rep # Rep # Rep # 0188 LCD4500Md1 0193 LCD4500Md12 019E PC41XXMd6 I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ____ __I _ _______I I _ ______I _ _______I _ ______I I _ ______I _ _ ______I I _ ______I _ _______I _ ______I 0189 LCD4500Md2...
Openings and Closings by User Rep # Rep # Rep # 01CE O/C User 001 01F9 O/C User 044 0224 O/C User 087 I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ______I _ _______I I _ ___ ___I _ _______I _ ______I I _ ______I _ _______I I _ ______I _ _______I _ ______I 01CF O/C User 002 01FA O/C User 045...
P r o g r a m m i n g W o r k s h e e t s Miscellaneous Openings and Closings Rep # Rep # Rep # 024E Quick Arm 0251 Auto Arm 0254-0256 For future use I _ ______I _ _______I I _ ______I _ _______I _ ______I I _ ____ __I _ _______I I _ ______I _ _______I _ ______I 024F Partial Closing...
DVAC Identifiers Function Bytes For alarm reports, bit number 7 of the function byte determines the status of the each printed event. Alarm Function Bytes In the following list, there are two entries for each event in the Function Byte column. The first number corresponds to an alarm;...
Bypass Function Bytes In the following list, there are two entries for each event in the Function Byte column. The first number corresponds to the bypassing of a zone; the second corresponds to the unbypassing. Each event will thus be printed in one of two ways. For example: Burglar Byp ZnXXX...
D V A C I d e n t i f i e r s Miscellaneous Function Bytes Function Byte Printer Message Computer Message 78/F8 By User 000-999 No transmission 79/F9 Control Act/Rst Pt000-999 RC/RO 000-999 7A/FA Service Req/Req Zn000-999 YX/YX 000-999 7B/FB Dealer Id/Id 000-999...