Becker R8/17RP+ Assembly And Operating Instructions Manual

Tubular drives for roller shutters

Advertisement

Quick Links

R8/17...R40/17
Version: RP(+)
Assembly and Operating Instructions
en
Tubular drives for roller shutters
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading

Summary of Contents for Becker R8/17RP+

  • Page 1 Version: RP(+) Assembly and Operating Instructions Tubular drives for roller shutters Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany www.becker-antriebe.com...
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Installation...................................  6 Assembling the drive ...............................  6 Undoing the mounting pin.............................. 7 Drive adapter safety catch ...............................
  • Page 3: General

    General These tubular drives are high-quality products with the following features: • Ideal for use with roller shutters • Automatic detection of limit positions thanks to intelligent electronic system with stop systems ∙ Secure anti-lifting device (RP+) ∙ Slight pressure applied to the roller shutter curtain makes it difficult to raise or reach under it (RP+) ∙...
  • Page 4: Safety Instructions

    Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • All work, including maintenance and cleaning, on electrical installations as well as other system parts must always be performed by authorised specialists, in particular qualified electricians.
  • Page 5 • Moving parts of drives must be installed at a height of over 2.5 m above floor level or any other surface from which access to the drive is gained. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in.
  • Page 6: Intended Use

    Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters. This type of tubular drive supports not only curtain attachment by means of springs but also mechanical anti-lifting devices (e.g., Zurfluh-Feller, Simu, GAH Alberts and Deprat).
  • Page 7: Undoing The Mounting Pin

    Undoing the mounting pin When pushed in, the mounting pin locks automatically. To undo the mounting pin, either insert the screwdriver, max. dia. 2.5 mm, (2) into the hole and push upwards, or push a flat-head screwdriver with a width of approx. 8mm (1) into the groove. Drive adapter safety catch Assembling the drive adapter with safety catch on the drive shaft Disassembling the drive adapter with safety catch on the drive shaft...
  • Page 8: Assembling And Disassembling The Drive Adapter With Separate Drive Adapter Safety Catch

    Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection Securing the drive against axial displacement In order to secure the drive against axial displacement, we recommend screwing the drive adapter to the tube.
  • Page 9: Mounting The Drive In The Tube

    Mounting the drive in the tube For profile tubes: In the case of some drive adapters, tolerances of the groove widths in different bar- rels can be offset by rotating the drive adapter into a different groove recess. These groove recesses have different sizes and allow the drive to fit exactly. For round tubes: First notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the tube.
  • Page 10: Setting The Limit Positions

    Setting the limit positions Programming unit for drives with electronic limit switching. Programming button Travel button Attention The programming unit is only designed for the commissioning, not for continuous opera- tion. Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement. Completion of installation following automatic setting of limit position "Stop"...
  • Page 11 Upper point to lower point There is no shading solution length adjustment with this limit position setting. Open to the desired upper limit position. Press the programming button of the programming unit for 3 seconds. ▻ The tubular drive makes a “click” sound to confirm. Then close to the desired lower limit position.
  • Page 12: Deleting The Limit Positions Using The Programming Unit

    Deleting the limit positions using the programming unit Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply. Please pause for 1 sec after the last drive command before beginning the deletion se- quence.
  • Page 13: Upper Anti-Freeze Mechanism

    Upper anti-freeze mechanism The upper anti-freeze mechanism helps to prevent the roller shutter from freezing in the upper limit position, as the roller shutter stops just before the upper stop. The distance from the upper stop is automatically cyclically checked and, if necessary, correc- ted.
  • Page 14: Information For The Electrician

    Information for the electrician Tubular drives with electronic limit switching can be connected in parallel. The maximum switching contact load of the switching equipment (timer, relay control, switch, etc.) must be observed. To operate drives with electronic limit switching, only use switch- ing elements (timers) that are not earthed via the drive.
  • Page 15: What To Do If

    What to do if...? Problem Cause Remedy The roller shutter curtain is raised un- 1. One or more attachments have Repair system; then re-program limit po- evenly or not at all. broken off. sitions. 2. Lath has broken off. Tubular drive overruns the upper limit po- Stops have broken off Repair system;...
  • Page 16: Sample Wiring Diagrams

    Sample wiring diagrams The assignment of the black and brown wires according to the direction of travel is de- pendant on how the drive is installed (mounted to the right or to the left). Controlling one/several drive(s) via a single switch/button...
  • Page 17 Central, group and individual control using Centronic UnitControl UC42 Central Control unit Mains 230 V / 50 Hz Central cable 230 V / 50 Hz (connection to further control units) Group 230 V / 50 Hz Individual Individual 230 V / 50 Hz 230 V / 50 Hz...
  • Page 18: Declaration Of Conformity

    Declaration of conformity...
  • Page 20 2010 300 302 0f     01/07/2016   ...

This manual is also suitable for:

R12/17rp+R20/17rp+R30/17rpR40/17rp

Table of Contents