A. SPIGOT SWITCH
When the spigot handle is opened the SPIGOT
switch will start the auger drive motor and
refrigeration systems. When the spigot handle is
closed, the auger drive motor and compressor will
remain on until the product in the barrel reaches the
proper consistency.
B. CLEAN-OFF-SERVE SWITCH
The CLEAN-OFF-SERVE switch is a three-position
rocker switch used to control the operation of the
refrigeration system and auger. When the switch is
placed in the CLEAN position, the refrigeration
system will be off and the auger will rotate for
cleaning.
When the switch is placed in the OFF position, the
refrigeration system and auger will not operate.
When the switch is placed in the SERVE position,
the refrigeration system and auger will operate
automatically. The switch should be placed in the
ON position for normal operation.
C. PUSH TO FREEZE SWITCH
The illuminating PUSH TO FREEZE switch is used
to start the freezing cycle. During the initial freeze
down, the CLEAN-OFF-SERVE rocker switch is
placed in the SERVE position. Then the PUSH TO
FREEZE switch is pressed until the drive motor and
compressor comes "ON."
After the gearmotor starts, there is a 3-second
delay before the compressor starts.
During the normal operation, the red PUSH TO FREEZE
switch will illuminate after the freezer has been in idle for
the pre-set time. Before drawing product, press the red
PUSH TO FREEZE switch if it is illuminated. Wait until
the green lens is illuminated before dispensing.
NOTE
If the freezer shuts off and the PUSH TO FREEZE
light flashes, you have an error condition. Turn
the CLEAN-OFF-SERVE switch to the OFF
position, correct the problem and turn the freezer
back on.
GREEN LIGHT
The green lens is used to indicate that the product has
reached the proper consistency and is ready to be
dispensed.
If the PUSH TO FREEZE lens is illuminated, push
the PUSH TO FREEZE switch and wait until the
green lens illuminates before dispensing.
MIX LOW LIGHT
The MIX LOW light is used to indicate when the hopper
is low on mix. When the light is illuminated fill the hopper
with mix.
FAILURE TO REFILL HOPPER IMMEDIATELY
MAY RESULT IN OPERATIONAL PROBLEMS.
D. DISPENSE RATE ADJUSTER
The dispense rate adjuster limits the opening of the
spigot.
To adjust product dispense rate, turn the adjusting
knob clockwise for slower flow and counterclockwise
for faster flow.
E. DOOR INTERLOCK SWITCH
When the door is securely fastened the freezer will
operate normally. When the door is removed, the
drive and compressor will not run.