To our customers,
we thank you for purchasing the eCelsius Performance Connect system. This solution is
manufactured by BodyCAP. This user guide aims to present the caracteristics and the way of
working of the solution and to support you in the installation and the use of the device. A proper
use of the solution does not imply specific training or skills; however please read carefully this
user guide and keep it on hand for review if needed. Failure to follow these instructions may
result in measurement error and personal or material injury damages. The responsibility of the
manufacturer and its distributors can not be engaged in case of misuse of the equipment. The
inspection and repair operation must be carried out by approved persons who have undergone
appropriate training.
The system is composed of:
- A (or several) disposable eCelsius Performance capsule(s) to monitor core tempe
rature through gastrointestinal tractus.
- A signaletic bracelet provided with each capsule.
- An activator and its power supply cable allowing turn on the capsule before inges
tion.
- An ePerf Connect gateway and its power supply cable allowing data temperature
recovering from 1 to 3 capsules simultaneously.
- An ePerf Mobile Android Application for Android Smartphone or Tablet (available on
Play Store) allowing to set up the ePerf Connect device and to visualize the data retrieved from
the device.
- An USB stick including user documentation.
Destination and use cases:
The eCelsius performance Connect system is designed to continuously measure core temperature
through gastrointestinal tractus in non-medical use cases. The eCelsius Performance capsule
must be swallowed. It is delivered in its original packaging and intended for a single use. It has
to be woken up thanks to the Activator and associated with the ePerf Connect device which
records the data and can return them to an Android Smartphone or Tablet through the ePerf
Mobile Application.
Declaration of conformity:
BodyCAP declares that the eCelsius Performance Connect solution is compliant with current
directives and regulations:
- 2011/65/UE, relative à la limitation de l'utilisation de certaines substances dangereuses dans
les équipements électriques et électroniques
- 2014/53/UE relative à la mise sur le marché d'équipements radioélectriques
- 1907/2006 concernant l'enregistrement, l'évaluation et l'autorisation des substances chimiques,
ainsi que les restrictions applicables à ces substances (REACH)
P063GUI001 - User guide eCelsius Performance Connect.1 - EN
5
Need help?
Do you have a question about the e Celsius Performance Connect and is the answer not in the manual?
Questions and answers