DISPLAY –"INFO" mode
Turn the control knob
to dispay the following informations:
A00 Real DHW temperature
A01 Real external temperature
A02 Modulating current %
(with N.G. = 30-230 mA dc; with LPG =
45-310 mA
dc)
A03 Boiler Output %
A04 CH set-point temperature
A05 Real CH temperature
A07 Flame signal %
(the ionisation signal normally is more than 2 microA)
Note: program lines from A06 - A08 - A09 are not used. "INFO" function remains active for 3 minutes.
To exit "INFO" function before this time repeat the operation as described in points 1...4 or cutting OFF
the power supply to the boiler.