Nice Plug-Control Instructions And Warnings For Installation And Use page 9

Smart switch type e/f
Table of Contents

Advertisement

Parameter:
41. LED ring colour when controlled device is on
Description:
When set to 1 or 2, LED ring colour will change depending on active power and parameter 40. Other colours are
set permanently and do not depend on power consumption.
Available settings:
0 - illumination turned off completely
1 - colour changes continuously depending on active power
2 - colour changes in steps depending on active power
3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow
8 - cyan, 9 - magenta
Default setting:
1
Parameter:
42. LED ring colour when controlled device is off
Description:
This parameter defines the illumination colour after turning off.
Available settings:
0 - illumination turned off completely
1 - LED ring is illuminated with a colour corresponding to the last measured power, before the controlled device
was turned off
3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow
8 - cyan, 9 - magenta
Default setting:
0
Parameter:
43. LED ring colour at the Z-Wave network alarm detection
Description:
This parameter defines the illumination colour in case of Z-Wave alarm.
Available settings:
0 - illumination turned off completely
1 - no change in colour. LED ring colour is determined by settings of parameters 41 or 42
2 - LED ring flashes red/blue/white
3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow
8 - cyan, 9 - magenta
Default setting:
2
Parameter:
50. Associations in Z-Wave network security mode
Description:
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Pa-
rameter is active only in Z-Wave network security mode. This parameter does not apply to 1st „Lifeline" group.
Available settings:
0 - none of the groups sent as secure
1 - 2nd group sent as secure
2 - 3rd group sent as secure
3 - 2nd and 3rd group sent as secure
Default setting:
3
Available settings:
0 - periodic reports are disabled
1-32000 (1-32000s) - report interval
Default setting:
3600 (1h)
Parameter:
59. Periodic energy reports
Description:
This parameter determines in what time interval the periodic energy reports are sent to the main controller.
Available settings:
0 - periodic reports are disabled
1-32000 (1-32000s) - report interval
Default setting:
3600 (1h)
Parameter:
60. Measuring energy consumed by the device itself
Description:
This parameter determines whether energy metering should include the amount of energy consumed by the
device itself. Results are being added to energy reports for first endpoint.
Available settings:
0 - function inactive
1 - function active
Default setting:
0
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
1 [byte]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Plug-Control and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents