Parameter:
12. Power reporting interval
Description:
This parameter defines the time interval of sending at most 5 standard power reports when the power changes by
the value set in parameter 11. The higher the value of parameter 12, the fewer reports the device will send.
By default Plug-Control sends up to 5 reports each 30 seconds, provided the power load changes by 15%.
Available settings:
5-600 (in seconds)
Default setting:
30 (30s)
Parameter:
13. Energy reporting threshold
Description:
This parameter specifies the minimum change in energy consumption (in relation to the previously reported), that
will result in sending a new report.
Available settings:
0 - energy reports inactive
1-500 (0.01-5kWh, step 0.01kWh) - threshold
Default setting:
10 (0.1kWh)
Parameter:
14. Power and energy periodic reports
Description:
This parameter defines time period between independent reports sent when changes in power load have not
been recorded or if changes are insignificant. By default reports are sent every hour.
Available settings:
0 - periodic reports inactive
5-32400 (in seconds)
Default setting:
3600 (1h)
Parameter:
15. Measuring energy consumed by Plug-Control itself
Description:
This parameter determines whether power metering should include the amount of power consumed by Plug-
Control itself. Results are being added to the value of power consumed by controlled device.
Available settings:
0 - function inactive
1 - function activated
Default setting:
0
Parameter:
20. Control of „On/Off (Button)" association group (2) devices
Description:
Controlling devices with the B-Button. This parameter is inactive in "Always On" mode (parameter 1).
Control as Plug-Control:
• switching Plug-Control on – switch the devices on (parameter 24)
• switching Plug-Control off – switch the devices off (parameter 24)
Control opposite to Plug-Control:
• switching Plug-Control on – switch the devices off
• switching Plug-Control off – switch the devices on
Available settings:
0 - control as Plug-Control
1 - control opposite to Plug-Control
Default setting:
0
Parameter:
21. DOWN value - „On/Off (Power)" association group (3)
Description:
Lower power threshold, used in parameter 23. DOWN value cannot be higher than a value specified in parameter
22.
Available settings:
0-24900 (0.0-2490.0W, step 0.1W)
Default setting:
300 (30W)
Parameter:
22. UP value - „On/Off (Power)" association group (3)
Description:
Upper power threshold, used in parameter 23. UP value cannot be lower than a value specified in parameter 21.
Available settings:
100-25000 (10.0-2500.0W, step 0.1W)
Default setting:
500 (50W)
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]