Notes:
•
Overload safety switch functionality is not an overload safety protection nor a short circuit protection. Circuit needs additional short circuit
and overload protection!
•
In extreme cases, reports may be sent every second if rapid and significant power load changes occur. Frequent reporting may overload
the Z-Wave network so values of parameters 10 and 11 should reflect significant changes in power load only.
•
Setting parameter 24 to appropriate value will result in:
» 0 - turning off associated devices,
» 1-99 - forcing level of associated devices,
» 255 - setting associated devices to the last remembered state or turning them on.
•
If "Always On" function is active (parameter 1), settings of parameter 31 are ignored.
•
The alarm may be cancelled by pressing and holding the B-button.