Nice Plug-Control Instructions And Warnings For Installation And Use page 8

Smart switch type e/f
Table of Contents

Advertisement

Parameter:
23. The response after exceeding defined power values
Description:
This parameter defines the way that 3rd association group devices are controlled. Depends on the actual mea-
sured power (as parameters 21 and 22 settings).
Available settings:
1 - turn the associated devices ON, once the power drops below DOWN value (parameter 21)
2 - turn the associated devices OFF, once the power drops below DOWN value (parameter 21)
3 - turn the associated devices ON, once the power rises above UP value (parameter 22)
4 - turn the associated devices OFF, once the power rises above UP value (parameter 22)
5 - combination of 1 and 4.
Turn the associated devices ON, once the power drops below DOWN value (parameter 21).
Turn the associated devices OFF, once the power rises above UP value (parameter 22).
6 - combination of 2 and 3.
Turn the associated devices OFF, once the power drops below DOWN value (parameter 21).
Turn the associated devices ON, once the power rises above UP value (parameter 22).
Default setting:
6
Parameter:
24. SWITCH ON value - „On/Off" association groups
Description:
The value of BASIC SET command frame sent to the devices associated in „On/Off" association groups (2, 3).
„On/Off (Button)" association group - in accordance with parameter 20.
„On/Off (Power)" association group - in accordance with parameter 23.
Available settings:
0-99 or 255
Default setting:
255
Parameter:
30. Active alarms
Description:
Define Z-Wave network alarms to which Plug-Control will respond.
Available settings:
1 - general alarm
2 - smoke alarm
4 - CO alarm
8 - CO2 alarm
16 - high temperature alarm
32 - flood alarm
Default setting:
63 (all)
Parameter:
31. Response to alarm frames
Description:
This parameter defines how Plug-Control will respond to alarms (device's status change).
In case of values 1 or 2 Plug-Control is operating normally and LED ring signals an alarm through time defined in
parameter 32 or until the alarm is cancelled.
In case of values 5 to 50 Plug-Control does not report status change, power changes, ignores BASIC SET com-
mand frames. After time defined in parameter 32 or after the alarm cancellation, connected device is set to the
previous state.
Available settings:
0 - no reaction,
1 - turn connected device on
2 - turn connected device off
5-50 (0.5-5.0s, step 0.1s) - cyclically change device state with set period
Default setting:
0
Parameter:
32. Alarm state duration
Description:
This parameter specifies the duration of alarm state. If a device sending an alarm frame through the Z-Wave net-
work sets alarm duration as well, this settings are ignored.
Available settings:
1-32400 (in seconds)
Default setting:
600 (10min)
Parameter:
40. Power load for violet colour
Description:
This parameter determines maximum active power value, which when exceeded, causes the LED ring flash violet.
Function is active only when parameter 41 is set to 1 or 2.
Available settings:
1000-30000 (100.0-3000.0W, step 0.1W)
Default setting:
25000 (2500W)
Parameter size:
1 [byte]
Parameter size:
2 [bytes]
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]