Advanced Parameters - Nice Plug-Control Instructions And Warnings For Installation And Use

Smart switch type e/f
Table of Contents

Advertisement

10

ADVANCED PARAMETERS

Plug-Control allows to customize its operation to user's needs. The settings are available in the interface of the Z-Wave controller.
Table A3 - Plug-Control - Advanced parameters
Parameter:
Description:
Available settings:
Default setting:
Parameter:
Description:
Available settings:
Default setting:
Parameter:
Description:
Available settings:
Default setting:
Parameter:
Description:
Available settings:
Default setting:
Parameter:
Description:
Available settings:
Default setting:
1. "Always On" mode
In this mode Plug-Control will turn on connected device permanently and will stop reacting to attempts of turning
it off (through Z-Wave network or pushing the B-button).
"Always On" function turns Plug-Control into a power and energy meter. Connected device will not be turned off
upon receiving an alarm frame from another Z-Wave device (parameter 31 will be ignored).
In "Always on" mode, connected device may be turned off after exceeding the power defined in parameter 3 or in
case of detecting current greater than 110% of rated current. In such cases, connected device can be turned on
again by pushing the B-button or sending a control frame. By default, overload protection is inactive.
0 - function inactive
1 - function activated
0
2. Remember device status before the power failure
This parameter determines how Plug-Control will react in the event of power supply failure (e.g. power outage or
taking out from the electrical outlet).
After the power supply is back on, Plug-Control can be restored to previous state or remain switched off.
This parameter is ignored in „Always On" mode - the device automatically turns ON after plugging it into the
socket.
0 - device remains switched off
1 - device restores the state from before the power failure
1
3. Overload safety switch
This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device will
be turned off even if "Always On" function is active (parameter 1).
Controlled device can be turned back on via B-button or sending a control frame. By default this function is inac-
tive.
CAUTION! - The device has a protection that will turn the load off in the case of detecting current greater than
110% of rated current (>12A). It is a safety function and it cannot be turned off. After its activation the load can
be turned on back again by pressing the B-button or sending a control frame. This function is independent of
overload safety switch set in the parameter no. 3.
0 - function inactive
10-30000 (1.0-3000.0W, step 0.1W) - power threshold
0
10. High priority power report
This parameter determines the minimum percentage change in active power that will result in sending power
report to the main controller with the highest priority in the Z-Wave network.
By default, Plug-Control immediately sends the power report if the power load changes by 80%.
1-99 - power change in percent
100 - reports are disabled
80 (80%)
11. Standard power report
This parameter determines the minimum percentage change in active power that will result in sending power
report to the main controller
Compared to parameter 10, the maximum number of reports sent is reduced (parameter 12) to 5 in a specified
time interval. In addition, the reports are not sent in mode, which may result in overloading the Z-Wave network.
By default changes in power load may be reported up to 5 times per 30 seconds, when power load changes by
15%.
1-99 - power change in percent
100 - reports are disabled
15 (15%)
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
2 [bytes]
Parameter size:
1 [byte]
Parameter size:
1 [byte]