Operation - Videx 4000 Series Manual

Digital to functional interface with built-in speaker unit & proximity reader
Hide thumbs Also See for 4000 Series:
Table of Contents

Advertisement

Available languages

Available languages

4000 Series
Art. 4204X
Digital to functional interface with built-in speaker unit & proximity reader
POWER SUPPLY
To power the button module connect one of the inbuilt IDC male connectors to the IDC male connector of the camera unit mod-
ule through the flat cable provided. Further buttons expansion modules can be connected to the free IDC male connector of the
previous expansion module (Fig. 3).
Art. CFL17
17 cm length flat cable
(Supplied)
Art. CFL45
45 cm length flat cable
(to be ordered separately)
Fig. 3
HOW TO CONNECT AN ELECTRIC LOCK
The "door-open" relay can operate either as "dry contact" or "capacitive discharge" mode.
• In "dry contact" operation mode the relay works in a traditional way, a power supply or a power source is needed
to operate the lock (12-24Vac/dc 2A max), and activation lasts according to the door opening time programmed.
• In "capacitive discharge" operation mode the relay's contacts, when active, supply directly the lock (12Vac/
dc 1A max) for a moment. You don't need a power supply for the lock and the door opening time pro-
grammed do not affect the activation time.
* NOTE: in "capacitive discharge" modality the relay time cannot be more than 6 seconds because it could overhead
the device.
A possibile deterioration of the mechanical performance of the electric lock, might cause the "capacitive discharge" to malfunction
in time. In case the electric lock is used in very dusty environments or in an abnormal climate condition, we suggest to use the "open
door" relay in "dry contacts" mode.
Fig. 4 Using capacitive discharge

OPERATION

Once the Art. 4204X has been programmed and connected correctly, it will generate upon each pressing of a push button, a code corre-
sponding to the PHONE ID (address programmed on the 8 way dip-switch inside each telephone) of the telephone being called.
Art. 4204X
- Installation instructions
12Vac/dc 1A Max
OR
12Vac 1.6A Max using Art. 321
24Vac/dc 2A Max using other power supplies
Fig. 5 Using separate P.S.U.
- 4 -
J1 Mode
H
Dry contacts
relay
L
H
Capacitive
discharge *
L
66251895 - V1.1 - 31/01/20