Before Calling For Service; Disposal - Hoshizaki KM-40C Instruction Manual

Self-contained crescent cuber
Hide thumbs Also See for KM-40C:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
4) When the display changes to "cln", pour the following amount of solution into the water tank carefully not to overflow it.
KM-40C:
2.0 litres
KM-60C:
2.5 litres
KM-80C:
3.0 litres
5) Rinse the bin liner with clean water to remove any solution spilled in the storage bin. Then, close the door.
6) Press the cleaning button (or wait for 15 minutes) to start the automated chemical cleaning.
7) The unit resumes the original state when the cleaning is over.
If the ice made after the automated chemical cleaning tastes wrong, immediately stop using the icemaker and call for service.
Fully Automated Chemical Cleaning (*)
* Available only for the fully automated cleaning model (-W) or when the fully automated cleaning kit (option) is used.
The fully automated cleaning kit automatically feeds a chemical (1250 ml of 40% citric acid solution) and descales the water
circuit at a desired frequency. Make necessary settings according to "II. 2. USER SETTINGS".
For further details, see the instruction manual of the fully automated cleaning kit ACK.

2. BEFORE CALLING FOR SERVICE

If the icemaker does not work properly or does not work at all, before calling for service, check that:
* The power is supplied to the unit.
* The water is turned on.
* The air filter is clean.
If the problem still exists, turn off the power supply, turn it back on, and press the reset button.
If the problem persists, check whether the error code "E" is indicated on the display or the dot at the center is on, and contact
your local Hoshizaki service agent.
If one of the following notice codes appears, follow the instructions below.
Code
n92
Abnormal high temperature. Clean air filter. Check for proper installation according to "I. 4. LOCATION".
n93
No chemical is left (when fully automated chemical cleaning kit (option) is used). Replace or refill chemical container,
and reset by user setting "U.55" (see "II. 2. USER SETTINGS"). To change frequency of notice, use user setting "U.49".
n99
Period of time set by user setting "U.60" (see "II. 2. USER SETTINGS") has passed and maintenance is required.
When maintenance is done, press reset button.
For further assistance or advice, contact your local Hoshizaki service agent.

3. DISPOSAL

Comply with local regulations regarding disposal of this appliance and its refrigerant gas. Before you scrap the appliance, take
off the door to prevent children trapped.
The insulation foaming agent used for the unit body contains flammable gas cyclopentane. With this in mind,
dispose of the product properly.
Risk of fire
WARNING
WARNING
Do not damage the refrigerant circuit.
Description
WARNING
10