Installation and Operation Manual
®
Thermo Scientific Jewett
Blood Bank Refrigerators

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Jewett XR60C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thermo Scientific Jewett XR60C

  • Page 1 Installation and Operation Manual ® Thermo Scientific Jewett Blood Bank Refrigerators...
  • Page 2 © 2008 Thermo Fisher Scientific. All rights reserved. ® “Suva ” is a registered trademark of DuPont. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.
  • Page 3 Thermo Scientific Jewett Blood Bank Refrigerators Installation and Operation 7. All models have been provided with an electric condensate Introduction evaporator located on the back of the cabinet. Periodic cleaning of the condensate pan will insure proper operation. This product is a complete packaged unit ready to operate when plugged into an electrical source.
  • Page 4: Temperature Control

    Thermo Scientific Jewett Blood Bank Refrigerators Installation and Operation TEMPERATURE CONTROL This refrigerator uses a Dixell XR60 temperature control: ºC Control operation is described in detail on the following three insert pages. The operating temperature setpoint for all blood bank refrigerators is pre-set to 4ºC at the factory and should not normally be changed for blood storage applications.
  • Page 5   ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV  At the end of defrost dripping time is started, its length is set in the FSt parameter. With Digital controller with defrost and fans management FSt =0 the dripping time is disabled. XR60C 3.3 CONTROL OF EVAPORATOR FANS The fan control mode is selected by means of the “FnC”...
  • Page 6: Main Functions

      ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV  5.1 HOW TO SEE THE ALARM DURATION AND MAX (MIN) TEMPERATURE 6.6 HOW TO LOCK THE KEYBOARD If the alarm LED is on, an alarm has taken place. To see the kind of alarm, the max (min) reached temperature and alarm duration do as follows: Keep pressed for more than 3 s the UP and DOWN keys.
  • Page 7: Digital Input

      ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV  • First defrost after start-up: (y = immediately; n = after the IdF time) 8.3 SERIOUS ALARM MODE (i1F = bAL) • dAF Defrost delay after continuous cycle: (0 ÷ 23.5h) time interval between When the digital input is activated, the unit will wait for “did” delay before signalling the the end of the fast freezing cycle and the following defrost related to it.
  • Page 8: Alarm Signals

      ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV  11.2 HOW TO PROGRAM AN INSTRUMENT USING A HOT KEY 14.2 XR60C – 120VAC OR 230 VAC (DOWNLOAD) Turn OFF the instrument.     Insert a programmed “Hot Key” into the 5 PIN receptacle and then turn the 8(3)A Controller ON.
  • Page 9: Installation

    Thermo Scientific Jewett Blood Bank Refrigerators Installation and Operation DRAWER SLIDE MOUNTING INSTRUCTIONS INSTALLATION AND REMOVAL OF DRAWERS 1.Push into slots in rear standard as shown in Step # 1. Make certain that the opposite drawer slides are in the same slots in the INSTALLATION opposite standards.
  • Page 10 Thermo Scientific Jewett Blood Bank Refrigerators Installation and Operation 8 Hinge And Latch Adjustment 8.2 Latch and Strike Adjustment 1. Latch is fastened to door. 2. For up or down adjustment (proper latch engagement) loosen mounting screws "B". 3. Strike plate "C" remains in position.
  • Page 11 Ulteriori informazioni sulla conformità di Thermo Fisher Scientific con queste Direttive, l’elenco delle ditte di riciclaggio nel Vostro paese e informazioni sui prodotti Thermo Scientific che possono essere utili alla rilevazione di sostanze soggette alla Direttiva RoHS sono disponibili sul sito www.thermo.com/ Conformité...
  • Page 12: If You Need Assistance

    Important For your future reference and when contacting the factory, please have the following information readily available: Model Number: Serial Number: Date Purchased: The above information can be found on the dataplate attached to the equipment. If available, please provide the date purchased, the source of purchase (manufacturer or specific agent/rep organization), and purchase order number.
  • Page 13 Thermo Fisher Scientific Inc. 275 Aiken Road Asheville, NC 28804 United States www.thermofisher.com 306098H01 Rev. E...