Example Of "Testcommand" Message; Table 11: Coding Of "Testcommand" (Example) - Siemens TC3 Series User Manual

Cellular engines
Table of Contents

Advertisement

TC3x Multiplexer User's Guide

9.5.2 Example of "TestCommand" message

An example for coding a "TestCommand" message is illustrated in Table 11.

Table 11: Coding of "TestCommand" (Example)

IEI coding
8 7 6 5 4 3 2 1 0x
1 0 0 1 1 1 1 1 F9
0 0 0 0 0 0 1 1 03
1 1 1 0 1 1 1 1 EF
0 0 0 0 1 0 1 1 25
0 0 1 0 0 0 1 1 23
0 0 0 0 0 1 1 1 21
0 0 0 0 0 1 0 0 04
0 0 0 0 0 0 0 1 39
X X X X X X X X XX
1 0 0 1 1 1 1 1 F9
TC3x_UG_01_V03.10 - Released
Information element name
START Flag
Address Field DLCI=0,C/R=0,EA=0
Control Field UIH Frame, P/F=0
Length LENGTH=18, EA=1
Type Field TestCommand, C/R=1, EA=1
Length Lenth=16, EA=1
TEMUX_VERSION
54
T
45
E
4D
M
55
U
58
X
56
V
45
E
52
R
53
S
49
I
4F
O
4E
N
39
Version number = 999
39
FCS (is calculated)
END Flag
Page 50/50