Plug the unused drain hole
To prevent unwanted leaks you must plug the unused
drain hole with the rubber plug provided.
BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS
1.
All wiring must comply with local and national electrical codes, regulations and must
be installed by a licensed electrician.
2.
All electrical connections must be made according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor units.
3.
lf there is a serious safety issue with the power supply, stop work immediately. Explain your
reasoning to the dient, and refuse to install the unit until the safety issue is properly resolved.
4.
Power voltage should be within 90-110% of rated voltage. lnsufficient power supply can
cause malfunction, electrical shock, or fire.
5.
lf connecting power to fixed wiring, a surge protector and main power switch should
be installed.
6.
lf connecting power to fixed wiring, a switch or circuit breaker that disconnects all poles
and has a contact separation of at least 1/8in (3mm) must be incorporated in the fixed wiring.
The qualified technician must use an approved circuit breaker or switch.
7.
Only connect the unit to an individual branch circuit outlet. Do not connect another
appliance to that outlet.
8.
Make sure to properly ground the air conditioner.
9.
Every wire must be firmly connected. Loose wiring can cause the terminal to overheat, resulting in
productmalfunction and possible fire.
10.
Do not let wires touch or rest against refrigerant tubing, the compressor, or any moving parts
with in the unit.
11.
lf the unit has an auxiliary electric heater, it must be installed at least 1 meter (40in) away
from any combustible materials.
12.
To avoid getting an electric shock, never touch the electrical components soon after the
power supply has been turned off. After turning off the power, always wait 10 minutes or
more before you touch the electrical components.
WARNING
Before performing any electrical or wiring work, turn off the main power to the system.
Step 6: Connect signal cable and power cables
The signal cable enables communication between the indoor and outdoor units. You must first choose the
right cable size before preparing it for connection.
NOTE: The cable conection of the indoor unit had been finished in the factory.
Cable Types
Indoor Power Cable (if applicable): H05VV-F or H05V2V2-F
Outdoor Power Cable: H07RN-F or H05RN-F
Signal Cable: H07RN-F
Minimum Cross-Sectional Area of Power and Signal Cables (For reference)
4
120
man_S60xx EU ('21) V3.indd 120
man_S60xx EU ('21) V3.indd 120
09-11-2021 09:05
09-11-2021 09:05