Computer Link Operation (Pr. 117 To Pr. 124) - Mitsubishi FR-E520-0.1KN Instruction Manual

Table of Contents

Advertisement

4.2.29 Computer link operation (Pr. 117 to Pr. 124)

Pr. 117 "station number"
Pr. 118 "communication speed"
Pr. 119 "stop bit length"
Pr. 120 "parity check presence/absence"
Pr. 121 "number of communication retries"
Pr. 122 "communication check time interval"
Pr. 123 "waiting time setting"
Pr. 124 "CR⋅ ⋅ ⋅ ⋅ LF presence/absence selection"
Used to perform required settings for RS-485 communication between the inverter and
personal computer.
! The motor can be run from the PU connector of the inverter using RS-485
communication.
Communication specifications
Conforming standard
Number of inverters connected
Communication speed
Control protocol
Communication method
Character system
Stop bit length
Terminator
Check
system
Waiting time setting
! For the data codes of the parameters, refer to Appendix 1 "Data Code List (page
171).
Parameter
Number
117
118
119
120
121
122*
123
124
* When making communication, set any value other than 0 in Pr. 122 "communication check
time interval".
RS-485
1:N (maximum 32 inverters)
Selectable between 19200, 9600 and 4800bps
Asynchronous
Half-duplex
ASCII (7 bits/8 bits) selectable
Selectable between 1 bit and 2 bits.
CR/LF (presence/absence selectable)
Parity check
Selectable between presence (even/odd) and absence
Sumcheck
Present
Selectable between presence and absence
Factory
Setting
0
192
Data length 8
1
Data length 7
2
1
0
9999
1
Setting Range
0 to 31
48, 96, 192
0, 1
10, 11
0, 1, 2
0 to 10, 9999
0 to 999.8 s, 9999
0 to 150ms, 9999
0, 1, 2
114