Download Print this page

Panasonic PT-53X54J Service Manual page 6

Hide thumbs Also See for PT-53X54J:

Advertisement

pin 1 on D-Board
4. Connect a H.V. meter (static type, class 0.1) with high voltage
leads to high voltage distributor on FBT.
5. Connect the 15 ~ 25 V DC variable power supply positive lead to
D34 or IC802 pin 2 (D Board) and negative lead to heat sink of
Q551 or D825
Procedures:
1. Apply a NTSC white pattern.
2. Turn PTV ON.
3. Adjust the picture or brightness controls so that the DVM reads
12.7 ± 0.4 volts.
4. Increase the variable power supply until set turns off. The set
should turn off at 12.7 ± 0.4 volts (DVM) and high voltage less than
36.4kV.
5. If the DVM reading is other than 12.7 ± 0.4 volts, readjust picture or
brightness control and repeat steps 3.
6. Turn off the variable supply and confirm that the set will turn on by
pulling out AC plug socket and connecting it again.
H.V. measurement
DVM and power supply connection
6

Advertisement

loading