13.2 Mechanical And Electrical Problems (cont.)

Table 3 (cont.)
Trouble
Machine will not start/restart or
repeatedly trips circuit breaker
or blows fuses (cont.)
Band saw does not come up to
speed.
24
891200_EVTBS16V Tilting Band Saw_Edition 1.indd 24
891200_EVTBS16V Tilting Band Saw_Edition 1.indd 24
Possible Cause
Miswiring of the unit.
Switch failure.
Extension cord is too light or too long.
Low current.
Remedy
Double check to confirm all electrical connec-
tions are correct. Reference the appropriate
wiring diagrams to make any needed correc-
tions.
If switch is suspect, you have two options: Have
a qualified electrician test the switch for func-
tion, or purchase a new start switch and estab-
lish if that was the problem on changeout.
Replace with adequate weight and length cord.
Contact a qualified electrician.