Routing The Control Unit Cables Into The Drive Module; Connections To The Drive Module; Connections To The Control Unit - ABB ACS880-04 Hardware Manual

Drive modules
Hide thumbs Also See for ACS880-04:
Table of Contents

Advertisement

WARNING!
Handle the fiber optic cables with care. When you unplug the cables, always
grab the connector, not the cable itself. Do not touch the ends of the fibers
with bare hands as the ends are extremely sensitive to dirt.

Routing the control unit cables into the drive module

Route the control unit connection cables to the drive module through the slot in the
middle front cover at the front or left side. First, remove the plate which covers the
slot. Then, install the rubber grommet (item 2) from the accessories box.

Connections to the drive module

1.
Connect power supply cable of the control unit to the ZPOW connector and the
ground wire of the cable to the ground terminal.
2.
Connect the BGDR cable to the BGDR connector.
3.
Connect the fiber optic cables to the V20 and V10 connectors.
ZPOW
1
BGDR
2
V10, V20
3

Connections to the control unit

Connect the fiber optic, power supply and BGDR cables to the control unit as follows:
1.
Thread the cables inside the back frame of the control unit.
2.
Connect the cables to the ZBIB board terminals.
1
Electrical installation 109
11

Advertisement

Table of Contents
loading