Configuring The Interface - Datalogic PowerScan Area Imager Quick Reference Manual

Industrial cordless handheld
Table of Contents

Advertisement

Configuring the Interface

CONFIGURING THE INTERFACE
Scan the appropriate programming bar code to select the
interface type for your system.
NOTE: Unlike some other programming features and
options, interface selections require that you scan only
one programming label. DO NOT scan an ENTER/EXIT label
prior to scanning an interface selection label.
Some interfaces require the scanner to start in the dis-
abled state when powered up. If you read one of these
interface selections by mistake, or if additional scanner
configuration is desired while in this state, pull the trigger
and hold for 5 seconds. The scanner will change to a state
that allows reading programming labels.
This procedure is allowed only once after the reader is
powered up. If it is necessary to repeat the procedure, you
must cycle power to the base charger before repeating.
RS-232 for use with OPOS/UPOS/JavaPOS
USB Com to simulate RS-232 standard interface
a. Download the correct USB Com driver from www.datalogic.com.
6
POWERSCAN™ PM96XX
SERIAL INTERFACE
RS-232 standard interface
Select RS232-STD
RS-232 Wincor-Nixdorf
Select RS232-WN
Select RS-232 OPOS
Select USB-COM-STD
a

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pm96xxPm96xx-hp

Table of Contents