Datalogic PowerScan Area Imager Quick Reference Manual page 27

Industrial cordless handheld
Table of Contents

Advertisement

ENVIRONMENTAL CHARACTERISTICS
Operating
Temperature
Recharging
Temperature
Storage Tempera-
ture
Humidity
Drop Resistance
Ambient Light
Immunity
Contaminants:
Spray/rain,
Dust/particulates
ESD Protection
a. NOTE: The higher the ambient temperature, the longer the charging time.
Optical Format
Imager Sensor
Illumination System
Aiming System
Reading Angle
Field of View
Print Contrast Ratio
-20° to 50° C (-4° to 122° F)
Recommended 0° to 35° C (32° to 95° F)
a
Max allowed 0° to 40° C (32° to 104° F)
-40° to 70° C (-40° to 158° F)
0 to 95% non-condensing
Withstands 50 drops from 2.4 m/8 ft @20°
C;
Withstands 50 drops from 2.0 m/6.6 ft @-
20° C
100,000 Lux
IP67 and IP65
20 KV
OPTICAL CHARACTERISTICS
1/4"
1280 H x 800 V
White LED
630 - 680 nm VLD
All models:Pitch: +/- 52°; Skew: +/- 52°
HP:
STD:
minimum 15%
38° x 24°
38° x 24°
QUICK REFERENCE GUIDE