Cleaning Of The Spray Gun - SATA SATAjet 4600 B Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 103
Operating Manual SATAjet 4600 B RP/HVLP
7.2. Adjust material flow
al flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
7.3. Adjust spray fan pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.

8. Cleaning of the spray gun

• Prior to cleaning, please disconnect the paint spray gun from the com-
pressed air circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty spray gun and gravity flow cup completely, dispose of paint
material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, lyes, bases, pickling agents, unsuitable
regenerates or other aggressive cleaning solutions!*
• Do not soak spray gun in cleaning solution! *Cleaning solution
should never penetrate the air passages!
• Drillings are to be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
[4-1], [4-2], [4-3] und [4-4] - materi-
Note!
Warning! Attention!
EN
41

Advertisement

Table of Contents
loading

Table of Contents