Operating Instructions SATAjet 3000 K RP/HVLP
8.

Cleaning of the Spray Gun

• Prior to cleaning, please disconnect the spray gun from the compressed air
circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty spray gun completely, dispose of paint material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, lyes, bases, pickling agents, unsuitable
regenerates or other aggressive cleaning solutions!*
• Do not soak spray gun in cleaning solution!*
• Drillings are to be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to be pressurised with clean compressed air
during the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the gun washing machine right
after the cleaning process!*
• Never use ultrasonic cleaning devices - leads to damage of noz-
zle components and gun surfaces!
• After cleaning, the spray gun, the material passages, the air
cap including thread have to be blown dry with clean com-
pressed air!*
* otherwise risk of corrosion
• Check spray pattern after cleaning the nozzle set!
• Further tips concerning cleaning can be found at www.sata.com/TV.