Exhaust System - FNM HPE Series Installation Manual

Marine diesel engines
Hide thumbs Also See for HPE Series:
Table of Contents

Advertisement

engine
stern drive
sea water intake
Figure 24 - Connection diagram of the double water intake (stern drive
In the case of twin installations (two engines), each engine
must have its own sea water circuit separate and independent
of the other engine.

5.4 Exhaust system

The installation of the exhaust system depends on the position
of the engine with respect to the waterline of the boat.
Failure to follow the rules contained in this paragraph may lead
to the infiltration of water into the engine, resulting in damage.
Comply with the instructions.
Correct positioning of the engine inside of the boat is
the responsibility of the installer who must respect
the waterline position.
5.4.1 Engine in stern drive configuration
In case of stern drive installations the correct positioning of the
engine depends on the specifications of the stern drive
installed.
Refer
to
stern drive
24 – FNM® Series HPE – Installation Manual
sea water intake flange
sea water
strainer
installations)
paragraph
4.2
waterline (worst case)
Engines with Mercruiser Bravo® stern drive on page 14 to see
the correct positioning of the stern drive assembly and the
engine inside the engine compartment.
Figure 25 - Engine exhaust in stern drive configuration
In case of stern drive installations the upper exhaust elbow (on
the engine)
must be fixed with a sleeve of appropriate
diameter to the discharge lower elbow (on the stern drive), as
shown in Figure 26. Use two clamps to each end of the sleeve
to ensure the appropriate seal.
Figure 26 - Exhaust sleeve in Stern drive version
The minimum height a in Figure 25 between the waterline and
the highest point of the upper exhaust elbow (on the engine) is
shown in the following table:
Engine
1.9HPE
2.4HPE
3.0HPE
5.4.2 Engine in Inverter / JetDrive / Saildrive
configuration
In case of inverter, JetDrive or Saildrive installations the upper
discharge elbow must be connected to the exhaust outlet on
engine
Distance a between
the waterline and the
Exhaust riser
highest point of the
exhaust [mm]
min 470
80 (3 3/16 in)
min 470
80 (3 3/16 in)
min 550
100 (3 15/16 in)
[mm]