Accessories Additional Pulley (Pto) - FNM HPE Series Installation Manual

Marine diesel engines
Hide thumbs Also See for HPE Series:
Table of Contents

Advertisement

Tank and
heat
exchanger
Return fitting
Auxiliary
thermostat
Return valve
(not provided)
Figure 59 - Wiring diagram for heating kit on 3.0 HPE base engine
Screw the flow connection on the head, near the cooling water
temperature sensor, removing the nut M16x1.25 in the point
shown in the following image:
Screw to be
removed
Figure 60 - Installation point of the boiler kit delivery connection on
3.0 HPE base engines.
Connect the 16 mm (5/8 in) diameter fitting to the heater input
circuit .
Insert the three-way return fitting cutting the sleeve between
the head and the connection pipe between the expansion tank
and auxiliary thermostat as shown in the following image:
Return fitting
Figure 61 - Installation point of the boiler kit return connection on 3.0
HPE base engines.
line free surface
Head
Delivery
fitting
Heater
(boiler)
Delivery valve
(not
supplied)
Delivery
fitting
Cutting line
Connect the two halves of the sleeve cut at the ends of the
connector while preserving the orientation shown in Figure 61
Connect the free end of the16 mm (8.5 in) diameter fitting to
the heating circuit output .
Use cable clamps provided with the kit to attach the sleeves to
the fittings.

8.2 Accessories Additional Pulley (PTO)

The engines of the HPE range may be prearranged with an
additional power take-off on the engine shaft. This possibility
involves the installation of an additional pulley for trapezoidal
toothed belts with one or more grooves.
Engine
1.3 HPE
1.9 HPE
2.4 HPE
3.0 HPE
The pulley coupling with the accessory device must be
correctly sized. The technical features of the additional pulley
vary depending on the model of the engine and are expressed
in the following table:
Number and Type of Additional
Engine
Grooves
1 x V-Belt Sect. SPB
1.3 HPE
DIN 2211
1.9 HPE
2 x V-Belt Sect. A
2.4 HPE
ISO R52-253
1 x V-Belt Sect. Z/SPZ ISO
3.0 HPE
4183:95
During the installation it is necessary to check:
1. The maximum power which can be transmitted through
the pulley
Maximum Power
@
Engine
@1000
2000
Anytime
rpm
rpm
1.3
≤3
-
-
HPE
kw
1.9
≤3
-
-
HPE
kw
2.4
≤3
-
-
HPE
kw
3.0
≤1
≤1 kw
-
HPE
kw
*: mm of misalignment between the pulleys on the distance
between the shafts:
FNM® Series HPE – Installation Manual – 45
Additional Pulley order code
already supplied with engine
3.017.016.1
with adapter 3.105.222.1
3.017.052.1
Rated diameter [mm]
125 (4 15/16 in)
100 (3 15/16 in)
80 (3 5/32 in)
Maximum radial
Maximum
force given by
tension force
tensioning
P
15 N
-
15 N
-
15 N
-
400 N
-
Maximum
misalignment
allowed
α = 0.5°
(β ~
8mm/m*)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents