    Operating Manual ProDevice ASM120 PPMS USER Table of contents Introduction ................4 Software and hardware requirements ........5 Installation of the software package ........5 Launching the software ............9 Working with the software ........... 11 Menu ................11 Communication ..............12 Status ................
  • Page 3: Introduction

    The ProDevice ASM120 PPMS USER software package jest is a tool for operation of the ProDevice ASM120 series degaussers. The package allows setting up selected key functional parameters, activation and deactivation of blockades and generation of simplified reports from the device's performance.
  • Page 4: Software And Hardware Requirements

    Install the ProDevice ASM120 Admin software package by launching the installer package with the installer file. The procedure opens the installer package interface window (Fig. 3.1. The start window of the ProDevice ASM120 Admin software installer) Fig. 3.1. The start...
  • Page 5 Operating Manual ProDevice ASM120 PPMS USER Fig. 3.2 Disk path selection window for the software package Fig. 3.3 Settings confirmation window for the software installation process www.prodevice.eu...
  • Page 6 Operating Manual ProDevice ASM120 PPMS USER ASM120 Fig. 3.4 Product installation progress window Fig. 3.5 Software installation finish window www.prodevice.eu...
  • Page 7 Installing the .NET Framework package version 4.0 or higher may require installing additional operating system components, as required by Microsoft Corp. If the user does not customise the installation, the ProDevice ASM120 PPMS USER software package is installed in the following default location: C:\Program Files\ProDevice\PPMS user.
  • Page 8: Launching The Software

    This port is not usually blocked on the computer; otherwise contact this computer's Administrator. Start the ProDevice ASM120 PPMS USER software by launching the start file accessed via the program shortcut which is displayed after the successful installation. The program can also be accessed via the Programs...
  • Page 9 The connection test is repeated until correct data transmission is established. Once correct communication with the device has been established, the software status line displays following message: "Connection established!" Fig. 4.1 The start screen of the ProDevice ASM120 USER software interface www.prodevice.eu...
  • Page 10: Working With The Software

    PPMS Authorisation – allows setting up and configuring the device blockade. • Date & time – allows configuring the date and time on the device. • Exit – closes the ProDevice ASM120 Admin software. • Language – the drop-down menu which allows selecting the software interface language. www.prodevice.eu...
  • Page 11: Communication

    Operating Manual ProDevice ASM120 PPMS USER 4.1.2. COMMUNICATION The function screen for establishing and configuring up the network connection with the device. Fig. 4.1.2.1 Communication function screen. Fig. 4.1.2.1 Communication function screen. The screen has fields with the following properties: Fig.
  • Page 12 Operating Manual ProDevice ASM120 PPMS USER ASM120 • Port – this field displays the current TCP/IP port over which the peripheral device communicates. The user cannot edit this field. • IP – this field displays the IP address of the device with which communication will be established.
  • Page 13: Status

    Operating Manual ProDevice ASM120 PPMS USER 4.1.3. STATUS The function screen which displays the information on the status parameters of the device. Fig. 4.1.3.1 Degausser Status function screen www.prodevice.eu...
  • Page 14 Operating Manual ProDevice ASM120 PPMS USER ASM120 It contains the following fields: Fig. 4.1.3.2 The Degausser Status fields • MAC address – this field displays the current MAC address of the device. • IP address – this field displays the current IP address of the device.
  • Page 15: Reports

    Operating Manual ProDevice ASM120 PPMS USER 4.1.4. REPORTS The functionality of the software tool allows generating reports of the device performance. The Administrator can generate a simplified report from the data read from the device; they can also generate an encrypted file with the device diagnostic data.
  • Page 16 Operating Manual ProDevice ASM120 PPMS USER ASM120 • Cycle interrupted by open tray – the device detected that the tray was opened when the capacitors were being charged; access level: Customer. • Cycle interrupted by power off – the device detected that the power was turned off when the capacitors were being charged;...
  • Page 17 Operating Manual ProDevice ASM120 PPMS USER full report include: the sequential number, the timestamp of the completed cycle start; the completed cycle number from the non-erasable counter, the measured value of the erasing cycle in the form of magnetic induction in the area in which the erased element is placed.
  • Page 18 Operating Manual ProDevice ASM120 PPMS USER ASM120 Fig. 4.1.4.2 The list table of events read from the device The screen has a set of function buttons which act as follows: Fig. 4.1.4.3 The Simplified Report screen function buttons • New – this function button allows generating a new report of the events recorded by the device.
  • Page 19 Clear – the button clears the function window with the listed report data. The button does not clear the events list in the connected ProDevice ASM120 device. The button remains disabled until correct communication is established with the device. www.prodevice.eu...
  • Page 20 Operating Manual ProDevice ASM120 PPMS USER ASM120 The following is an example report generated as a *.pdf file. The report header contains the information about the report type (Full Report), the MAC address of the device from which the report was generated and the full date of generation.
  • Page 21: Ip Settings

    Operating Manual ProDevice ASM120 PPMS USER 4.1.5. IP SETTINGS The function screen which allows changing the current IP address of the device. Fig. 4.1.5.1 Degausser settings function screen Fig. 4.1.5.1 Degausser IP function screen The screen has fields with the following properties: Fig.
  • Page 22 Operating Manual ProDevice ASM120 PPMS USER ASM120 • Port – this field displays the current TCP/IP port over which the peripheral device communicates. The user cannot edit this field. • IP – this field displays the current IP address of the device with which communication has been be established.
  • Page 23: Time & Date

    Operating Manual ProDevice ASM120 PPMS USER 4.1.6. TIME & DATE The function screen which allows adjusting the date and time of the device clock. Fig. 4.1.6.1 Date & Time function screen The screen has fields with the following properties: Fig. 4.1.6.2 The Date & Time screen fields...
  • Page 24 REMOTE CHANGE OF THE BLOCKADE – STEP BY STEP INSTRUCTIONS If the Customer uses the preset limit of removal cycles, they should do the following steps: In ProDevice ASM120 ADMIN, enter the PPMS BLOCKADE CHANGE menu. Click the LOAD button.
  • Page 25: Authorisation

    Operating Manual ProDevice ASM120 PPMS USER 4.1.7. AUTHORISATION The function screen which allows the user to do the initial Authorisation Procedure. The Authorisation Procedure is based on the rights delegation mechanism. The delegation mechanism involves exchange of encrypted files. The user uses the application to generate an encrypted Key File which contains the data for device identification (MAC address, Device Password) and the data on the non-erasable counter.
  • Page 26 ASM120 AUTHORISATION – STEP BY STEP INSTRUCTIONS When the preset limit of removal cycles is used, do the following steps: In ProDevice ASM120 ADMIN, enter the PPMS AUTHORISATION menu. Click the CREATE button. After selecting the save location of the generated file, click SAVE.
  • Page 27 Operating Manual ProDevice ASM120 PPMS USER The screen has fields with the following properties: Fig. 4.1.7.2 The Authorisation screen fields • Cycle available – this field displays the value of the counter of remaining cycles of the device. This counter decrements with each completed cycle.
  • Page 28: Exit

    4.1.9. LANGUAGE The Language drop-down list can be accessed in the software Menu and changes the interface language of ProDevice ASM120 PPMS USER. The software interface language is changed directly after selecting the language option in the drop-down list. THE CONFIGURABLE AND MONITORED DEVICE...
  • Page 29 Operating Manual ProDevice ASM120 PPMS USER THE PRODEVICE ASM120 PPMS USER ALSO ALLOWS TO: • Create the Key File which enables setting the cycle count blockade of the device based on the Authorisation File for blockade setting. • Check the device RTC.
  • Page 30: Error Messages

    Operating Manual ProDevice ASM120 PPMS USER ASM120 5.1.1. ERROR MESSAGES The software tool has a set of messages with encountered errors. The following lists the diagnostic messages. • Communication establishment attempt in progress – this message is displayed in the status line of the software interface when communication is lost between the device and the software.
  • Page 31 Fabryczna 20A, 31-533 Krakow, Poland tel. no. +48 12 379 30 30 e-mail: info@prodevice.eu customer service: serwis@prodevice.eu If you wish to customise a device or the software, add a new interface language or if you have other suggestions for device development, please contact us! info@prodevice.eu...

Table of Contents