12. Automatic recognition and decoding may recognize the codes incorrectly or
not at all. In such a case, the operator must evaluate whether the result is
valid or not and, if necessary, he should repeat the measurements with
corrected settings or perform them several times.
8

Operating the device

In some basic functions, the REA VeriCube can be operated with the device buttons
The on/off button
With this button, the device is turned on and off. The PoE power supply
needs to communicate with the connected device, this results in some
turn-on delay. It ends as soon as the left orange LED on the Ethernet
socket of the device lights up. Prior to that, the device cannot be turned
on.
The Scan button
A measurement is performed by observing the ROI, which is determined
(manually or automatically) on the PC
The F1 button
The F1 button turns on the live picture display so that the code can be
positioned. The live picture has a lower resolution than the
measurement picture, and the brightness is adjusted automatically so
that something becomes visible in the picture. This adjustment of the
brightness can be completely different than the adjustment for the
measurement with calibrated exposure settings.
© REA Elektronik GmbH, Teichwiesenstraße 1 D-64367 Muehltal
REA VeriCube Operating Manual Version 2.16 – 11/2020
Page 38 of 119