Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.
Operating Instructions and Parts Manual
Description
An effluent system consists of a pump,
control switch and a basin. The system is
generally controlled by a float switch with a
plug-in plug which accepts the pump plug
and in turn plugs into a 115 volt outlet.
The float switch is a wide angle differential
switch that rises with the liquid level and
turns the pump on. As the liquid level
decreases, the float lowers and turns the
pump off. This pump is intended for use in
domestic sump or effluent lift stations. It is
suitable for pumping effluent, wastewater,
ground water and other nonexplosive,
noncorrosive liquids with up to 3/4" solids.
Effluent pump will
NOTICE
not pump raw
sewage or any substance exceeding
3/4" size.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY and
to PREVENT EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
CAUTION
!
potentially
Specifications
Power supply requirements.............115V, 60 hz
Circuit requirements ........................15 amps (min)
Motor duty .......................................Intermittent
Motor ................................................115V, 1 Phase, 1725 RPM
Horsepower .....................................1/3
Motor full load .................................11 amps
Liquid temperature range ...............40°F to 120°F
Max. operating position ..................45
Dimensions .......................................13-1/2" x 11"
Intake ................................................2"
Discharge ..........................................2" NPT female, 3" NPT male
Cut-in level (factory set) ..................18"
Cut-out level (factory set)................10"
Differential .......................................8"
Switch................................................90
Power cord........................................16 gauge 3 conductor w/plug
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2002
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
NOTICE
information, that if not followed, may
cause damage to equipment.
General Safety Information
1. Know the pump application, limitations,
and potential hazards.
WARNING
!
Do not use to pump
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in
flammable and/or explosive atmospheres.
Use pump only with liquids compatible
with pump component materials. Failure
to follow this warning can result in
personal injury and/or property damage.
2. Make certain that the power source
(electric motor) conforms to the
requirements of the equipment.
DANGER
!
Disconnect power before
servicing. If the power dis-
connect is out of sight, lock
in the open position and
tag it to prevent unexpected
application of power. Failure to do so
could result in fatal electrical shock!
o
from vertical
o
wide angle mechanical
tether switch
For parts, product & service information
visit www.waynepumps.com
Effluent
Pump
Notice indicates
important
Construction
Motor body material .......................Cold rolled steel
Motor housing .................................Glass reinforced polypropylene
Volute ...............................................Glass reinforced ABS
Impeller.............................................Glass reinforced PBT
Seal plate ..........................................Cast Iron
Shaft seal ..........................................End faced mechanical
Performance
GALLONS PER HOUR AT TOTAL HEAD IN FEET
Model
10
EFL33
3600
Model EFL33
3. Release all pressure within the system
before servicing any component.
4. Drain all liquids from the system before
servicing.
5. Secure the discharge line before starting
the pump. An unsecured discharge line
will whip, possibly causing personal
injury and/or property damage.
6. Check hoses for weak and worn
condition before each use, making
certain that all connections are secure.
7. Periodically inspect the pump and
system components. Perform routine
maintenance as required (See
Maintenance Section).
8. Provide a means of pressure relief for
pumps whose discharge line can be shut-
off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times when
working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors a safe distance from the
work area. Make workshop child-
proof with padlocks, master switches,
and by removing starter keys.
10. When wiring an electrically driven pump
such as this, follow all electrical and safety
codes, as well as the most recent National
Electrical Code (NEC) and the Occupation-
al Safety and Health Act (OSHA).
15
20
1300
330101-001 7/02
0

Advertisement

loading

Summary of Contents for Wayne EFL33

  • Page 1 Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Model EFL33 Operating Instructions and Parts Manual 3. Release all pressure within the system...
  • Page 2 Operating Instructions and Parts Manual The pump motor is Installation WARNING WARNING equipped with In any installation NOTICE automatic resetting thermal protector Risk of electric shock! where property and may restart unexpectedly. Never connect the green (or damage and/or personal injury might Protector tripping is an indication of green and yellow) wire to a result from an inoperative or leaking...
  • Page 3 Limited Warranty For one year from the date of purchase, Wayne Water Systems ("Wayne") will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship.
  • Page 4 7. Shut off valve closed 7. Open valve For Replacement Parts, call 1-800-237-0987 Please provide following information: Address parts correspondence to: Wayne Home Equipment - Model number - Serial number (if any) 100 Production Drive Tethered length to be 3” + .25”...