Wayne EWP10 Installation Instructions Manual

Water powered back-up sump pump system
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Installation Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Description
The EWP10 is a water powered back-
up sump pump. It does not replace a
regular pump. This pump is designed
for use with municipal water systems
and is inteded to be used as an
emergency backup to your existing
sump pump.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe
the following symbols.
an imminently hazardous situation
which, if not avoided, will result in
death or serious injury.
a potentially hazardous situation which,
if not avoided, could result in death or
serious injury.
a potentially hazardous situation which,
if not avoided, may result in minor or
moderate injury.
important information, that if not
followed, may cause damage to
equipment.

General Safety

Information
Do not use to pump flammable
or explosive fluids such as
gasoline, fuel oil, kerosene,
etc. Do not use in a flammable and/or
explosive atmosphere. Pump should only
be used to pump clear water. Fatal injury
and/or property damage could result.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safe keeping.
© 2007 Wayne Water Systems
Water Powered
Back-up Sump
Pump System
If the basement has water
or moisture on the floor, do
not walk on wet area until all
power is turned off. If the shutoff box
is in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.
must be used on the primary sump
pump discharge.
must only be used to pump clear water.
This pump is not designed to handle
effluent, salt water, brine, laundry
discharge or any other application
which may contain caustic chemicals
and/or foreign materials. Pump damage
may occur if used in these applications
and will void warranty.
Installation
Installation of this unit may take
several hours. Before disabling your
main pump, have ready an appropriate
means of evacuating the sump.
Danger
1. Turn power to main pump off.
indicates
2. Pump must be installed using 1¼"
or 1½" rigid PVC pipe. Do not use
flexible drain hose.

Pump Installation

Warning
indicates
The EWP10 can be installed with a
separate dedicated discharge line
(Figure 1, Method 1) or tied into the
existing sump pump line (Figure 2,
Caution
Method 2).
indicates
existing AC pump. Failure to follow this
warning could result in fatal electrical
Notice
shock.
indicates
3. Verify that the existing AC pump
is in good working order. If the
AC pump is questionable, it is
recommended that the unit be
replaced.
4. Remove any silt or accumulated
debris from the sump pit and
surrounding area.
5. Locate the EWP10 in an ideal
position in the sump pit. The
ideal position is approximately
2" from the bottom of the sump
pit and located so that it does
not interfere with any part of the
existing sump pump.
For parts, product & service information
www.waynepumps.com
visit
6. Method 1 Installation:
(Figure 1) Cut and dry-fit rigid
PVC pipe to the discharge of the
water powered back-up pump.
Cement all fittings and discharge
pipe after all pipe has been cut
and dry-fit together.
A check
line installation will vary depending on
valve
individual circumstances. Using sound
plumbing practices, route the discharge
pipe to an exterior wall by the shortest
path. Keep turns to a minimum because
This
they reduce the flow output of the pump.
pump
The pipe that exits the building structure
should be sealed and sloped downward
so the water will not freeze in the pipe.
Method 2 Installation:
(Figure 2) Cut the existing main
pump discharge line and cement
a "T" or "Y" fitting. Measure,
cut and dry-fit the pipe required
to connect the EWP10 to the
installed "T" or "Y" fitting.
Cement all fittings and pipe.
7. Shut off the municipal water
supply. Install a rigid water
supply line to the sump area.
Include a shut-off valve in the
supply line. Flush the supply line
of all debris before installing the
automatic valve.
8. Connect the automatic valve
assembly with brass vacuum
breaker to the supply line. Is
should be located about 6" above
the basement floor or sump pit
cover. The supply line needs to be
supported.
9. Attach the hose coupling and
Unplug
washer to the brass vacuum
the
breaker of the automatic valve
assembly.
10. Attach the "L" bracket to the
automatic control valve using the
two screws supplied.
11. Install the float rod by threading
the two parts together. Using
the large coupler, secure the rod
connection by threading the top
screw to the top part and the
bottom screw to the bottom part.
12. Install a small coupler and the
float to the float rod by inserting
the float rod through the center
of the float. Insert a small coupler
about ½" above the bottom of
the float rod and tighten the
fastener. Tighten the first small
coupler installed.
EWP10
The
discharge
353300-001 7/07

Advertisement

Table of Contents
loading

Summary of Contents for Wayne EWP10

  • Page 1: Pump Installation

    Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Description The EWP10 is a water powered back- up sump pump. It does not replace a regular pump. This pump is designed...
  • Page 2: Installation

    EWP10. Verify this on/off level of the EWP10 is higher than the on level of the main sump pump. 17. Reconnect power to the main sump pump. The water level in the pit should lower to the off point of the main sump pump.
  • Page 3 Typical Installation with Submersible Pump with a Separate Discharge Pipe Water-Powered Backup Sump Figure 1 Typcial Installation with Submersible Pump Check valve Water-Powered Backup Sump Figure 2 Water Supply Water Supply EWP10 Main Sump Pump Check valve Main Sump Pump www.waynepumps.com...
  • Page 4: Replacement Parts

    Figure 3 Limited Warranty For two years from the date of purchase, Wayne Water Systems Division (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship.
  • Page 5: Informaciones Generales De Seguridad

    Protéjase a sí mismo y a los demás observando la información de seguridad. El no cumplir con estas instrucciones podría provocar lesiones personales y/o daños materiales. Conserve estas instrucciones para futura referencia.. Descripción La EWP10 es una bomba de sumidero de respaldo accionada por el agua. No sustituye una bomba normal. Esta bomba ha sido diseñada para uso con...
  • Page 6: Guía De Diagnóstico De Averías

    EWP10 se apaga. Verifique que este nivel de encendido/apagado de la EWP10 quede más arriba del nivel de encendido de la bomba de sumidero principal. Acción a tomar 1.
  • Page 7 Figura 1 Instalación típica con bomba sumergible Válvula de retención Bomba de Sumidero de Respaldo Accionada por Agua Figura 2 Suministro de agua Suministro de agua 7 Sp EWP10 Bomba de sumidero principal Válvula de retención Bomba de sumidero principal...
  • Page 8: Garantía Limitada

    Figura 3 Garantía Limitada Durante un año a partir de la fecha de compra, Wayne Water Systems (“Wayne”) reparará o reemplazará para el comprador original, según lo que decida, cualquier pieza o piezas de su Juego para estanque, Bombas de resumideros, Bombas de agua (“Producto”) que después de un examen Wayne encuentre que tenían defectos...

Table of Contents