4
MOUNTING SIDE
Select the corresponding mounting side.
The sensor then learns its environment and automatically
determines the detection field(s). Both red LEDs flash slowly and
the 3 visible laser beams automatically light up during 30 seconds.
:
IMPORTANT
Test the good functioning of the installation before leaving the premises.
TEACH-IN
Launch a teach-in
after changing the sensor position
when new objects are added to or changed in the detection zone.
During teach-in, the sensor learns its surroundings and adapts the
detection field shape to these. Objects in the detection field will be cut out.
Stay outside of the detection field to avoid disturbances.
right
left
WITH BACKGROUND
The sensor memorizes the
floor as reference point
and signals a fault when its
orientation is changed.
3 s
Wait for the sensor to learn its environment
or lock it by remote control.
Stay outside of the detection field
to avoid disturbances.
left
right
WITHOUT BACKGROUND
No reference point, no signal.
max. 30 s
centre
7