Dimensional drawing
Specification, condenser unit
W1 Width
D1 Depth (hail guard included)
H1 Height
Electrical
Operating power
Minimum circuit ampacity
Maximum circuit HVACR breaker size
Outdoor condensing unit operating limits
(air temperature)
Maximum refrigerant line run length
Maximum line rise above evaporator
Evaporator mounting above condenser
Maximum refrigeration line drop without oil trap
Refrigerant charge
Approximate ship weight
Approximate net weight
NOTE:
1. Suction line must be insulated. Liquid line does not require insulation.
Remote 1810, 2110 series ice machine
H1
Horizon Elite 1810 series
30.00" (76.2 cm) – all models
38.50" (97.8 cm) – all models
25.75" (65.4 cm) – all models
single phase – 208‑230/60/1
three phase – 208‑230/60/3
single phase – 6.0 kW
three phase – 3.6 kW
single phase – 26.2 A
three phase – 15.7 A
single phase – 45 A
three phase – 25 A
min ‑20 F (‑29 C)
max 120 F (49 C)
75' (22.9 m)
35' (10.7 m)
15' (4.6 m)
15' (4.6 m)
14.5 lb required at installation
305 lb (138 kg)
295 lb (134 kg)
W1
D1
Horizon Elite 2110 series
30.00" (76.2 cm) – all models
38.50" (97.8 cm) – all models
25.75" (65.4 cm) – all models
single phase – 208‑230/60/1
three phase – 208‑230/60/3
single phase – 6.2 kW
three phase – 4.6 kW
single phase – 27.1 A
three phase – 19.9 A
single phase – 45 A
three phase – 30 A
min ‑20 F (‑29 C)
max 120 F (49 C)
75' (22.9 m)
35' (10.7 m)
15' (4.6 m)
15' (4.6 m)
14.5 lb required at installation
305 lb (138 kg)
295 lb (134 kg)